Allied-telesis AlliedView-EMS 4.0.1 DEVICE MANAGEMENT Uživatelský manuál Strana 216

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 411
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 215
Open TCP Connections
Displays open TCP connections information.
Ping Polling
Ping Status
Displays the status of the Ping polling.
Note - The current firmware version does not allow the Ping Status parameter to be
configured.
Ping Parameters
Displays basic information of the Ping module.
Note - Valid MIB Set values for the Timeout parameter should range from 1 to 60.
However, the current firmware version allows the user to enter values in the range
[-4294967295 to -1, 1 to 4294967295] inclusive. But attempting to enter values
greater than 65535 will cause the new value to be converted to its equivalent wrap-
around value; i.e., 65536 will become 0, 65537 will become 1, and so on.
Note - Valid MIB S et values for the Time Interval parameter should range from 0 to
604800. However, the current firmware version allows the user to enter values in
the range [-9223372036854775808 to 9223372036854775807] inclusive. But
attempting to enter values greater than 999999999 will cause the new value to be
converted to its equivalent wrap-around value; i.e., 9999999990 will become
1410065398, 9999999991 will become 1410065399, and so on.
Note - Valid MIB Set values for the Number of Packets parameter should range from
1 to 4294967295. However, the current firmware version does not allow Device
Manager to display the correct value greater than 2147483647. Attempting to enter
values greater than 2147483647 will cause the new value to be converted to its
equivalent wrap-around value; i.e. 2147483648 will become -2147483648,
2147483649 will become -2147483647, and so on.
Note - The current firmware version only allows the Address parameter to be
configured if the Protocol parameter is set to OSI.
Note - Valid MIB Set values for the Data Pattern parameter should range from
[0-4294967295] inclusive. However the current firmware version does not allow
Device Manager to display correct values greater than 4286578687. Attempting to
enter values greater than 4286578687 will cause the new value to be converted to
the following values:
4286578688 - 4294934527: 8388608 - 16744447
4294934528 - 4294967167: 32768 - 65407
4294967168 - 4294967295: 128 - 255
Ping Statistics
Displays statistics of the Ping polling.
AlliedView™-EMS 4.0.1 Device Management Guide Page 216 of 411
Zobrazit stránku 215
1 2 ... 211 212 213 214 215 216 217 218 219 220 221 ... 410 411

Komentáře k této Příručce

Žádné komentáře