AlliedView™-EMS 4.0.3 Device Management Guide Page 450 of 468
AT-MCF2012LC
10/100Base-TX to 100BaseFX (LC, 2km, MM)
LED State Description
DUPLEX
Green
Orange
The port is operating in full-duplex mode.
The port is operating in half-duplex mode.
LT Green Link Test is enabled
ML Green Missing Link is enabled
SML Green Smart Missing Link is enabled
Context Menu
Note - Valid MIB Set values for the Port Operation Mode parameter are "smart
missing link", "missing link" and "link test". However, the current firmware version
allows the Port Operation Mode parameter to be set to "oam bypass" or "oam
visible".
Note - The current firmware version does not allow the Port Ingress Rate Limit
and Port Egress Rate Limit parameters to be configured. Attempting to set these
parameters to valid values will result in the error message: " The error occurred
with 'Set' operation. Error: bad value.".
Note - The current firmware version returns inconsistent values on the Port
Operation Mode parameter.
AT-MCF2012LC/1