Allied-telesis AT-S95 CLI Uživatelský manuál Strana 196

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 392
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 195
Page 196
Allied Telesis
AT-S95 Management Software CLI Users Guide
7/e3 Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power.
Input Power – Measured RX received power.
Tx Fault – Transmitter fault
LOS – Loss of signal
console>
show fiber-ports optical-transceiver detailed
Power
Port Temp Voltage Current Output Input TX LOS
[C] [Volt] [mA] [mWatt] [mWatt] Fault
------ ------ ------- ------- ------- ----- ------ -----
7/e1 48 5.15 50 1.789 1.789 No No
7/e2 43 5.15 10 1.789 1.789 No No
7/e3 Copper
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power in milliWatts
Input Power – Measured RX received power milliWatts
Tx Fault – Transmitter fault
LOS – Loss of signal
Zobrazit stránku 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 391 392

Komentáře k této Příručce