Allied-telesis AT-MC1008/SP Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Počítačový hardware Allied-telesis AT-MC1008/SP. Allied Telesis AT-MC1008/SP User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - AT-MC1008/SP

AT-MC1008/GBAT-MC1008/SPGigabit Media ConvertersInstallation GuidePN 613-50654-00 Rev B

Strany 2

Preface10Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Descriptio

Strany 3 - Compliance Statement

AT-MC1008 Series Installation Guide11Where to Find Web-based GuidesThe installation and user guides for all Allied Telesyn products are available in p

Strany 4

Preface12Contacting Allied Telesyn This section provides Allied Telesyn contact information for technical support as well as sales and corporate infor

Strany 5 - Contents

13Chapter 1OverviewThe AT-MC1008 Series Media Converters are Gigabit Ethernet bridging converters. They offer a wide range of features and capabilitie

Strany 6

Chapter 1: Overview14IntroductionThe AT-MC1008/GB is a 1000Base-TX copper to GBIC (Gigabit Interface Connector) media converter. The AT-MC1008/SP is a

Strany 7

AT-MC1008 Series Installation Guide15AT-MC1008/SP Media Converter The AT-MC1008/SP media converter features: One 1000Base-TX twisted pair port  One

Strany 8

Chapter 1: Overview16Key FeaturesThe AT-MC1008 Series Media Converters come with the following features: Copper RJ-45 twisted pair connector  GBIC p

Strany 9

AT-MC1008 Series Installation Guide171000Base-TX Twisted Pair PortEach AT-MC1008 Series converter features one fixed 1000 Mbps twisted pair port. The

Strany 10

Chapter 1: Overview18Table 2 lists the twisted pair port cabling specifications.Auto MDI/MDI-XThe twisted pair port on the AT-MC1008 Series converter

Strany 11

AT-MC1008 Series Installation Guide191000Base Fiber Optic GBIC Slot on the AT-MC1008/GB ConverterThe AT-MC1008/GB converter features one GBIC slot on

Strany 12 - Contacting Allied Telesyn

Copyright © 2005 Allied Telesyn, Inc.www.alliedtelesyn.comAll rights reserved. No part of this publication may be reproduced without prior written per

Strany 13 - Overview

Chapter 1: Overview201000Base Fiber Optic SFP Slot on the AT-MC1008/SP ConverterThe AT-MC1008/SP converter features one SFP slot on the front panel. T

Strany 14 - Introduction

AT-MC1008 Series Installation Guide21MODE Push ButtonThe MODE push button is used to toggle between the three operation modes: Link Test (LT), Missing

Strany 15 - 12VDC

Chapter 1: Overview22fiber optic cabling, the unit would drop the link to the twisted pair port.The value to this type of network monitoring and fault

Strany 16 - Key Features

AT-MC1008 Series Installation Guide23LEDsThere are four types of LEDs on the AT-MC1008 Series converters, as shown in Figure 7: Status LED Fiber Opt

Strany 17 - 1000Base-TX Twisted Pair Port

Chapter 1: Overview24Twisted pair port LEDsThe twisted pair port LEDs indicate the operating status of the twisted pair port on the AT-MC1008 Series c

Strany 18 - Auto MDI/MDI-X

AT-MC1008 Series Installation Guide25MODE push button LEDsThe MODE push button LEDs indicate the operating status of the three operation modes: Link T

Strany 19 - AT-MC1008/GB Converter

Chapter 1: Overview2612VDC Power SupplyThe 12VDC-version media converters come with the AC/DC power adapter illustrated in Figure 8. This is an approv

Strany 20 - Converter

AT-MC1008 Series Installation Guide27Network TopologiesStandalone TopologyA standalone topology uses only one media converter between the end-nodes. F

Strany 21 - MODE Push Button

Chapter 1: Overview28Back-to-Back TopologyIn some network configurations you may want to interconnect two media converter in what is referred to as a

Strany 22 - Smart MissingLink

29Chapter 2Installing the Media ConverterThis chapter explains how to install an AT-MC1008 Series converter and contains the following sections:  “Ve

Strany 23 - Status LED

3Electrical Safety and Emission Compliance StatementStandards: This product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A,

Strany 24 - Twisted pair port LEDs

Chapter 2: Installing the Media Converter30Verifying Package ContentsMake sure the following items are included in your package. If any item is missin

Strany 25 - MODE push button LEDs

AT-MC1008 Series Installation Guide31Planning the InstallationBe sure to observe the following guidelines when planning the installation of your media

Strany 26 - 12VDC Power Supply

Chapter 2: Installing the Media Converter32Selecting a SiteWhen selecting a site for your media converter, observe the following guidelines: Select a

Strany 27 - Network Topologies

AT-MC1008 Series Installation Guide33Pluggable Equipment: The socket outlet should be installed near the equipment and should be easily accessible. 

Strany 28 - Back-to-Back Topology

Chapter 2: Installing the Media Converter34Caution: Installation of the equipment in a rack should be such that the amount of air flow required for sa

Strany 29 - Chapter 2

AT-MC1008 Series Installation Guide35Installing a GBIC TransceiverTo install a GBIC transceiver in an AT-MC1008/GB converter, perform the following pr

Strany 30 - Verifying Package Contents

Chapter 2: Installing the Media Converter362. Slide the GBIC transceiver into a GBIC slot on the converter, as shown in Figure 11, until it clicks int

Strany 31 - Planning the Installation

AT-MC1008 Series Installation Guide37Installing an SFP TransceiverTo install an SFP transceiver in an AT-MC1008/GB converter, perform the following pr

Strany 32 - Reviewing Safety Guidelines

Chapter 2: Installing the Media Converter384. Slide the SFP transceiver into an SFP slot on the converter, as shown in Figure 12.Figure 12. Installing

Strany 33

AT-MC1008 Series Installation Guide39Installing an AT-MC1008 Series Converter on a DesktopThis section explains how to install an AT-MC1008 Series con

Strany 34

Electrical Safety and Emission Compliance Statement4Important: Appendix C contains translated safety statements for installing this equipment. When y

Strany 35 - Installing a GBIC Transceiver

Chapter 2: Installing the Media Converter40Installing the Media Converter in the AT-MCR12 ChassisNoteFor detailed descriptions and installation proced

Strany 36

AT-MC1008 Series Installation Guide412. Securely position the converter chassis onto the mounting guide with the front tab (Tab A) inserting into the

Strany 37 - Installing an SFP Transceiver

Chapter 2: Installing the Media Converter42Cabling the Media ConverterPerform the following procedures to connect the data cables to the converter por

Strany 38 - AT-MC100

AT-MC1008 Series Installation Guide432. Connect the appropriate optical cable to the GBIC transceiver, as shown in Figure 18.Figure 18. Connecting Cab

Strany 39

Chapter 2: Installing the Media Converter444. Power ON the converter as instructed in “Powering On the Media Converter” on page 47.5. Power ON the end

Strany 40

AT-MC1008 Series Installation Guide452. Connect the appropriate optical cable to the transceiver, as shown in Figure 20.Figure 20. Connecting to the S

Strany 41

Chapter 2: Installing the Media Converter464. Power ON the converter as instructed in “Powering On the Media Converter” on page 47.5. Power ON the end

Strany 42 - Cabling the Media Converter

AT-MC1008 Series Installation Guide47Powering On the Media Converter Once the AT-MC1008 Series converter is ready to be used, perform the following pr

Strany 43

Chapter 2: Installing the Media Converter483. Plug the AC/DC adapter to a power outlet, as shown in Figure 23. Refer to “Technical Specifications” on

Strany 44 - Media Converter

AT-MC1008 Series Installation Guide49Warranty RegistrationWhen you have finished installing the product, register your product by completing the enclo

Strany 45 - AT-MC1008/

5ContentsElectrical Safety and Emission Compliance Statement ... 3Preface ...

Strany 47

51Chapter 3TroubleshootingFollow the guidelines below to test and troubleshoot the installation in the event a problem occurs.If the PWR LED is OFF, d

Strany 48

Chapter 3: Troubleshooting52If the LINK LED for the fiber optic port is OFF, do the following: Verify that the end-node connected to the port is ON a

Strany 49 - Warranty Registration

53Appendix ATechnical SpecificationsPhysicalDimensions: W x D x H105 mm x 95 mm x 25 mm(4.12 in x 3.75 in x 1.0 in)Weight: 294 g (10.4 oz)TemperatureO

Strany 50

Appendix A: Technical Specifications54Agency CertificationsRFI Emissions FCC Class A, EN55022 Class A, C-TICK, CEImmunity EN55024Electrical Safety EN6

Strany 51 - Troubleshooting

55Appendix BCleaning Fiber Optic ConnectorsThis section describes how to clean fiber optic connections. The fiber optic connector consists of a fiber

Strany 52

Appendix B: Cleaning Fiber Optic Connectors56This appendix provides the following procedures:“Using a Cartridge-Type Cleaner” on page 56 “Using a Sw

Strany 53 - Technical Specifications

AT-MC1008 Series Installation Guide572. Place the ferrule tip on the exposed cleaning surface and rub the ferrule in a downward direction, as shown in

Strany 54 - Agency Certifications

Appendix B: Cleaning Fiber Optic Connectors58NoteAlways keep a dust cap on a fiber optic cable when it is not in use.NoteDo not touch the end face of

Strany 55 - Appendix B

AT-MC1008 Series Installation Guide59To clean a recessed ferrule using a swab, perform the following procedure.1. Insert the swab into the adapter as

Strany 56 - PUSH OPENPUSH OPEN

Contents6LEDs ... 23Status LED...

Strany 58 - Using a Swab

61Appendix CTranslated Electrical, Safety, and Emission InformationImportant: This appendix contains multiple-language translations for the safety sta

Strany 59

Appendix C: Translated Electrical, Safety, and Emission Information62Laser Safety NoticesElectrical Safety Notices1 Warning: Class 1 Laser product.2 W

Strany 60

AT-MC1008 Series Installation Guide6311 Warning: As a safety precaution, install a circuit breaker with a minimum value of 20 Amps between the equipme

Strany 61 - Emission Information

Appendix C: Translated Electrical, Safety, and Emission Information6421 Warning: The power source for the gateway unit should be located near the unit

Strany 62 - Laser Safety Notices

AT-MC1008 Series Installation Guide6531 Warning: Do not look directly at the fiber optic cable ends or inspect the cable ends with an optical lens.32

Strany 63

Appendix C: Translated Electrical, Safety, and Emission Information66Telecommunications Compliance Notices41 Warning: When using your telephone equipm

Strany 64

AT-MC1008 Series Installation Guide67LasersicherheitshinweiseElektrische Sicherheitshinweise1 Achtung: Laserprodukt der Klasse 1.2 Achtung: Blicken Si

Strany 65

Appendix C: Translated Electrical, Safety, and Emission Information6811 Achtung: Als Sicherheitsvorkehrung sollte ein Ьberlastschalter mit einem minim

Strany 66

AT-MC1008 Series Installation Guide6920 Vorsicht: Bei der Innenraummontage des Gateway-Gerдts ist darauf zu achten, dass es in einer staubfreien Umgeb

Strany 67 - Lasersicherheitshinweise

AT-MC1008 Series Installation Guide7Appendix BCleaning Fiber Optic Connectors ... 55Us

Strany 68

Appendix C: Translated Electrical, Safety, and Emission Information7029 Zur zuverlдssigen Stromversorgung des Gerдts sollte ein dedizierter Stromkreis

Strany 69

AT-MC1008 Series Installation Guide71Telekommunikationskonformitдtshinweise41 Achtung: Bei der Verwendung Ihrer Telefonausrьstung sollten zur Reduzier

Strany 70

Appendix C: Translated Electrical, Safety, and Emission Information72Avisos de seguridad láserAvisos de seguridad elйctricas1Atenciуn: Producto lбser

Strany 71

AT-MC1008 Series Installation Guide7311 Atenciуn: Como medida de seguridad, instale un disyuntor con un valor mнnimo de 20 A entre el equipo y la toma

Strany 72 - Avisos de seguridad láser

Appendix C: Translated Electrical, Safety, and Emission Information7421 Atenciуn: La toma elйctrica de la unidad de puerta de enlace debe estar situad

Strany 73

AT-MC1008 Series Installation Guide7532 Atenciуn: Esta unidad puede tener mбs de un cable de alimentaciуn. Para reducir el peligro de electrocuciуn, d

Strany 74

Appendix C: Translated Electrical, Safety, and Emission Information76Avisos de conformidad de telecomunicaciones41 Atenciуn: Cuando utilice su equipo

Strany 75

AT-MC1008 Series Installation Guide77Avis de sécurité laserAvis de sйcuritй йlectrique1 Avertissement: Produit laser de classe 1.2 Avertissement: Ne p

Strany 76

Appendix C: Translated Electrical, Safety, and Emission Information7811 Avertissement: Par mesure de sйcuritй, installer un coupe-circuit d’une intens

Strany 77 - Avis de sécurité laser

AT-MC1008 Series Installation Guide7920 Attention: Si le pйriphйrique servant de passerelle est installй а l’intйrieur, s’assurer qu’il se trouve dans

Strany 79

Appendix C: Translated Electrical, Safety, and Emission Information8029 Utiliser des circuits d’alimentation ou des unitйs de conditionnement dйdiйs p

Strany 80

AT-MC1008 Series Installation Guide81Tйlйcommunications – Avis de conformitй41 Avertissement: Les prйcautions йlйmentaires de sйcuritй doivent кtre sy

Strany 81

Appendix C: Translated Electrical, Safety, and Emission Information82Indicazioni sulla sicurezza laserIndicazioni sulla sicurezza elettrica1 Avvertenz

Strany 82

AT-MC1008 Series Installation Guide8311 Avvertenza: Per precauzione, installare un salvavita con un valore minimo di 20 ampere tra l'apparecchiat

Strany 83

Appendix C: Translated Electrical, Safety, and Emission Information8421 Avvertenza: La fonte di alimentazione dell'unitа gateway deve essere posi

Strany 84

AT-MC1008 Series Installation Guide8532 Avvertenza: Questa unitа potrebbe disporre di piщ cavi di alimentazione. Per ridurre il rischio di scosse elet

Strany 85

Appendix C: Translated Electrical, Safety, and Emission Information86Indicazioni per la conformitа con le norme sulle telecomunicazioni41 Avvertenza:

Strany 86

AT-MC1008 Series Installation Guide87Лазерная безопасностьЭлектрическая безопасность1 Внимание: лазерный продукт, класс 1.2 Внимание: Не смотрите прям

Strany 87 - Лазерная безопасность

Appendix C: Translated Electrical, Safety, and Emission Information8810 Во всех странах: Инсталлируйте продукт в соответствии с национальными нормами

Strany 88

AT-MC1008 Series Installation Guide8920 Предостережение: Если шлюзовая установка инсталлируется в помещении, позаботьтесь, чтобы в помещении не было п

Strany 89

9PrefaceThis guide contains instructions on how to install the AT-MC1008 Series Gigabit Media Converter and contains the following sections: “Safety

Strany 90

Appendix C: Translated Electrical, Safety, and Emission Information9030 Внимание: Корпус может быть тяжелым и поднять его может быть сложно. Allied Te

Strany 91

AT-MC1008 Series Installation Guide91Телекоммуникационное соответствие41 Внимание: При использовании телефонного оборудования, всегда следует обращать

Příbuzné modely AT-MC1008/GB

Komentáře k této Příručce

Žádné komentáře