613-001065 Rev. Dx600 Series Layer 3 Gigabit Ethernet Switchesx600-24Tsx600-24Ts/XPx600-48Tsx600-48Ts/XPInstallation Guide
10Translated Safety StatementsImportant: The indicates that a translation of the safety statement is available in a PDF document titled “Translated
11ContentsPreface ...
Contents12Chapter 2: Virtual Chassis Stacking ...
13Figure 1. x600-24Ts Switch - Front and Rear Panels...
Figures14
15Table 1. Safety Symbols ...
Tables16
17Chapter 1 OverviewThis chapter contains the following sections: “Introduction” on page 18 “Switch Descriptions” on page 19 “10/100/1000Base-T Twi
Chapter 1: Overview18IntroductionThe x600 Series Switches are managed Gigabit Ethernet switches that act as standalone units. There are four Basic Lay
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide19Switch DescriptionsThe following sections describe the x600-24Ts, x600-24Ts/XP, x600
Copyright © 2009 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T
Chapter 1: Overview20x600-24Ts/XPSwitchThe x600-24Ts/XP switch has the following hardware features: 24 10/100/1000Base-T ports Four Gigabit Ethernet
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide21x600-48Ts Switch The x600-48Ts switch has the following hardware features: 44 10/10
Chapter 1: Overview22x600-48Ts/XPSwitchThe x600-48Ts/XP switch has the following hardware features: 44 10/100/1000Base-T ports Four Gigabit Ethernet
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide2310/100/1000Base-T Twisted Pair PortsThis section describes the twisted pair ports on
Chapter 1: Overview24Cable Type The cabling requirements for a 10/100/1000Base-T port are: For 10 Mbps operation: Standard TIA/EIA 568-B-compliant Ca
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide25SFP Transceiver SlotsAll of the x600 Series switches feature slots for four optional
Chapter 1: Overview26XFP Transceiver SlotsThe x600-24Ts/XP and the x600-48Ts/XP Switches have two slots for optional XFP 10 Gigabit Ethernet transceiv
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide27Redundant Twisted Pair PortsFour of the twisted pair ports on the x600-24-Ts and x60
Chapter 1: Overview28SD Card SlotAll of the x600 Series Switches have an SD card slot which is designed for an SD card which stores configuration file
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide29Port LEDsThe following sections describe the twisted pair port, SFP, and XFP LEDs. S
3PrefaceThis guide contains the installation instructions for the x600 Series Layer 3 Gigabit Ethernet Switches. This preface contains the following s
Chapter 1: Overview30SFP LEDs Each SFP transceiver slot on the x600 switches has one LED, defined in Table 3.XFP TransceiverSlot LEDsEach 10 Gigabit E
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide31System Status LEDsThe system status LEDs on the front panel display general status i
Chapter 1: Overview32Stack LEDsThe STACK LEDs reflect the status of the two Stack ports on the AT-StackXG Stacking Module. To locate the Stack LEDs, s
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide33Both the x600-24Ts/XP and x600-48Ts/XP switches have one Secure Digital (SD) LED, de
Chapter 1: Overview34Terminal PortThe terminal port is used to establish a local (out-of-band) management session with the switch. You establish a loc
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide35AT-RPS3204 Redundant Power SupplyThe RPS connector on the rear panel of the switch c
Chapter 1: Overview36AT-LBM (Loop Back) ModuleThe x600-48Ts/XP switch is shipped from the factory with an AT-LBM module installed in its expansion slo
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide37VCS Stacking ModuleA Virtual Chassis Stack (VCS) is a group of x600 Layer 3 Gigabit
Chapter 1: Overview38AC Power ConnectorThe x600 switches have a single AC power supply socket on the rear panel, which has autoswitch AC inputs. To po
39Chapter 2: Virtual Chassis StackingThis chapter contains the following sections: “VCStackTM Introduction” on page 40 “Features of VCStacking” on p
Preface4Product DocumentationFor overview information about the software features of the AlliedWare Plus Operating System Software which runs on the x
Chapter 2: Virtual Chassis Stacking40VCStackTM IntroductionA Virtual Chassis Stack (VCStack) is a group of physically separate switches that are conne
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide41AT-StackXG Modules, Cables, and ConnectionsThe stacks are connected via the stacking
Chapter 2: Virtual Chassis Stacking42Ring ConfigurationA virtual stack using x600 switches can comprise up to 4 stack members connected in a ring topo
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide43Table 9. State Change Table1. The fallback action on a slave is first to run the fal
Chapter 2: Virtual Chassis Stacking44Resiliency LinkConfigurationsvia Switch PortsTwo resiliency-link configurations that connect to switch ports are
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide45Resilient StackedTopologyWhere network connectivity uptime is a major criteria, you
Chapter 2: Virtual Chassis Stacking46Stack FormationA virtual chassis stack (VCS) always contains a master plus a number of stack members. To be part
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide47The stack also assigns a Stack Member-ID number to each member. This number provide
Chapter 2: Virtual Chassis Stacking48the stacked switches, via the AT-StackXG interfaces, and therefore do not appear on the user network. Initially t
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide49Table 10. Stacking LED FunctionsRunning QoS within a VCS stackIn general you can app
x600 Layer 3 Gigabit Ethernet Switch Installation Guide5Starting a Management SessionFor instructions that describe how to start a local management se
Chapter 2: Virtual Chassis Stacking50VCS FailureRecoveryIf the stack master either fails, or is removed, the other stack members will decide which of
x600 Series Layer 3 Gigabit Ethernet Switches Installation Guide51StackMaintenanceAdding a Stack MemberAn unstacked switch can be added to an existing
Chapter 2: Virtual Chassis Stacking52
53Chapter 3Installing the HardwareThis chapter provides procedures to install an x600 switch. The chapter contains the following sections: “Reviewing
Chapter 3: Installing the Hardware54Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the switche
x600 Layer 3 Gigabit Ethernet Switch Installation Guide55All Countries: Install product in accordance with local and National Electrical Codes. E8Ci
Chapter 3: Installing the Hardware56Unpacking a SwitchTo unpack a switch, perform the following procedure:1. Remove all components from the shipping p
x600 Layer 3 Gigabit Ethernet Switch Installation Guide57Installing the Power Cord Retaining ClipPerform the following procedure to install the power
Chapter 3: Installing the Hardware58Installing the Switches in an Equipment RackPerform the following procedure to install each switch in a standard 1
x600 Layer 3 Gigabit Ethernet Switch Installation Guide59Figure 24. Attaching Rack-Mount Brackets5. Install the second rack-mount bracket on the other
Preface6Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Description
Chapter 3: Installing the Hardware60Resetting the SwitchYou may need to reset the switch after upgrading the firmware or after you have made a configu
x600 Layer 3 Gigabit Ethernet Switch Installation Guide61AT-StackXG Module InstallationOverview A Virtual Chassis Stack (VCS) is a group of x600 Layer
Chapter 3: Installing the Hardware62Installing theAT-StackXGModuleTo install the AT-StackXG module, perform the following procedure:1. Remove the modu
x600 Layer 3 Gigabit Ethernet Switch Installation Guide63CautionDo not force AT-StackXG module into place. Doing so may damage the connector pins on t
Chapter 3: Installing the Hardware64NoteDo not cable AT-StackXG module until you have prepared the switch’s Alliedware Plus Operating System software
65Chapter 4Cabling the Network PortsThis chapter contains the instructions for attaching network cables to an x600 switch. The chapter contains the fo
Chapter 4: Cabling the Network Ports66Twisted Pair and Fiber Optic Cable SpecificationsTwisted PairCableSpecificationsTable 11 lists the cabling speci
x600 Layer 3 Gigabit Ethernet Switch Installation Guide67SFP/XFPTransceiverCableSpecificationsThe cable specifications for an optional SFP or XFP tran
Chapter 4: Cabling the Network Ports68Installing SFP/XFP TransceiversReview the following guidelines before installing an optional SFP or XFP transcei
x600 Layer 3 Gigabit Ethernet Switch Installation Guide693. Position the transceiver with the label facing up.4. Slide the transceiver into the slot u
x600 Layer 3 Gigabit Ethernet Switch Installation Guide7Where to Find Web-based GuidesThe installation and user guides for all Allied Telesis products
Chapter 4: Cabling the Network Ports706. For the x600-48Ts and x600-48Ts/XP switches, verify that handles on the top two SFP modules are in the up pos
x600 Layer 3 Gigabit Ethernet Switch Installation Guide71Installing an XFPTransceiverTo install an XFP transceiver in an x600 switch, perform the foll
Chapter 4: Cabling the Network Ports725. Repeat this procedure to install a second XFP transceiver or go to “Cabling the Twisted Pair and Fiber Optic
x600 Layer 3 Gigabit Ethernet Switch Installation Guide73Cabling the Twisted Pair and Fiber Optic PortsObserve the following guidelines when connectin
Chapter 4: Cabling the Network Ports74Powering on a SwitchTo power on a switch, perform the following procedure:1. Position the power cord retaining c
x600 Layer 3 Gigabit Ethernet Switch Installation Guide754. Start a local management session on the unit by performing the next procedure.Starting a L
Chapter 4: Cabling the Network Ports76Warranty RegistrationFor warranty information and registration, go to the Allied Telesis web site at www.alliedt
77Chapter 5TroubleshootingThis chapter contains information about how to troubleshoot a switch in the event a problem occurs. Sections in the chapter
Chapter 5: Troubleshooting78Power LED is OffCheck the PWR LED on the front of the switch. If the LED is off, indicating that the unit is not receiving
x600 Layer 3 Gigabit Ethernet Switch Installation Guide79Twisted Pair Port Link LED is OffWhen a twisted pair port on the switch is connected to a pro
Preface8Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support as well as sales and corporate informa
Chapter 5: Troubleshooting80SFP or XFP LED is OffWhen a fiber optic port on the switch is connected to a properly operating end node, the Link LED for
x600 Layer 3 Gigabit Ethernet Switch Installation Guide81Transceiver is Installed but the Status is “Not Present”If a SFP or XFP transceiver is instal
Chapter 5: Troubleshooting82System Fault LED is BlinkingA blinking FAULT LED indicates that the switch is updating the active boot configuration file
x600 Layer 3 Gigabit Ethernet Switch Installation Guide83System Fault LED is Steadily OnIf the system FAULT LED is steadily on, a problem has occurred
Chapter 5: Troubleshooting84Cannot Establish a Local (Out-of-Band) Management SessionIf you are unable to establish a local (out-of-band) management s
x600 Layer 3 Gigabit Ethernet Switch Installation Guide85Switch Functions IntermittentlyIf a switch functions intermittently, check the system hardwar
Chapter 5: Troubleshooting86Issues with Virtual Stacking Chassis ConfigurationFor information on issues with stacking, refer to the Allied Telesis Inc
87Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D):x600-24Ts 44 mm x 440 mm x 305 mm(1.72 in. x 17.34 in. x 12.0 in.)x6
Appendix A: Technical Specifications88Power SpecificationsMaximum Power Consumption:x600-24Ts 76 wattsx600-24Ts/XP 76 wattsx600-48Ts 123 wattsx600-48T
x600 Layer 3 Gigabit Ethernet Switch Installation Guide89RJ-45 Twisted Pair Port PinoutsFigure 41 illustrates the pin layout of an RJ-45 connector and
9Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-
Appendix A: Technical Specifications90Table 14 lists the pin signals when a port operating at 1000 Mbps.Table 14. Pin Signals - 1000 MbpsPinout Pair1P
x600 Layer 3 Gigabit Ethernet Switch Installation Guide91RJ-45 Style Serial Terminal Port PinoutsTable 15 lists the pin signals on the RJ-45 style ser
Appendix A: Technical Specifications92RPS 21-pin D-combo Port and Connector PinoutsFigure 42 illustrates the pin layout of the RPS 21-pin D-combo port
x600 Layer 3 Gigabit Ethernet Switch Installation Guide9316 Ground17 Ground18 +12.0 VDC sense19 Ground20 No connectA-1 +12.0 VDCTable 16. RPS 21-pin C
Appendix A: Technical Specifications94
Komentáře k této Příručce