AT-S85 and AT-S97 Management Software User’s Guide
141
Stacking Port Link A Stack port on the management module or the
AT-MCF2000S Stacking Module established or lost
its link to another Stack port.
Report
Major Level Messages
Chassis Managership
Acquire
A media converter module assumed control of the
backplane in the chassis to determine system
information, as it was initializing its management
software.
Report
Chassis Managership
Release
A media converter module released control of the
backplane.
Report
Chassis Reset The chassis was reset with the SYSTEM RESET
CHASSIS command.
Report
Cold Boot A media converter module loaded its boot loader and
management software after receiving power. It
generates this message when the chassis is
powered on or if it is installed while a unit is powered
on.
Report
Fan # Failure A cooling fan in a power supply or fan module
stopped.
Report
A cooling fan resumed operating after having
stopped.
Clear
High Temperature
Threshold
A module’s operating temperature exceeded the
temperature threshold set with the SYSTEM SET
MODULE command.
Report
A module’s operating temperature returned below its
temperature threshold.
Clear
Module Reset A media converter module started the process of
initializing its boot loader and AT-S85 Management
Software after it was reset with the SYSTEM RESET
MODULE command. The completion of the
initialization process is signaled with the Warm Boot
message.
Report
Warm Boot A media converter module completed the
initialization of its management software after being
reset with the SYSTEM RESET MODULE
command.
Report
Table 18. Event Messages (Continued)