613-000985 Rev. AManagementSoftwareAT-S101User’s GuideFor use with the AT-GS950/8POE Gigabit Ethernet WebSmart SwitchVersion 1.0.0

Strany 2

Preface10Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per

Strany 3 - Contents

Chapter 8: Simple Network Management Protocol (SNMP)100SNMP OverviewYou can manage a switch by viewing and changing the management information base (M

Strany 4

AT-S101 Management Software User’s Guide101Community String AttributesA community string has attributes for controlling who can use the string and wha

Strany 5

Chapter 8: Simple Network Management Protocol (SNMP)102Trap receivers are the devices, typically management workstations or servers, that you want to

Strany 6

AT-S101 Management Software User’s Guide103Default SNMP Community StringsThe AT-S101 Management Software provides two default community strings: publi

Strany 7

Chapter 8: Simple Network Management Protocol (SNMP)104Creating an SNMP CommunityThis procedure explains how to create an SNMP community.To create an

Strany 8

AT-S101 Management Software User’s Guide105Modifying an SNMP CommunityUse the following procedure to modify the access level or a community name of an

Strany 9

Chapter 8: Simple Network Management Protocol (SNMP)106Deleting an SNMP CommunityUse the following procedure to delete an existing SNMP community in t

Strany 10 - Document Conventions

AT-S101 Management Software User’s Guide107Creating a Host TableUse the following procedure to create a Host Table. 1. From the menu on the left side

Strany 11

Chapter 8: Simple Network Management Protocol (SNMP)108Modifying a Host Table EntryTo modify the IP address or community name of an entry in the Host

Strany 12 - Contacting Allied Telesis

AT-S101 Management Software User’s Guide109Deleting a Host Table EntryUse the following procedure to delete a Host Table entry. 1. From the menu on th

Strany 13 - Chapter 1

AT-101 Management Software User’s Guide11Where to Find Web-based GuidesThe installation and user guides for all Allied Telesis products are available

Strany 14 - Switch’s IP Address

Chapter 8: Simple Network Management Protocol (SNMP)110Enabling or Disabling TrapsTo enable or disable a trap for an SNMP community, perform the follo

Strany 15

AT-S101 Management Software User’s Guide111Modifying TrapsTo modify the SNMP version, IP address, or community name of a trap, perform the following p

Strany 16

Chapter 8: Simple Network Management Protocol (SNMP)112Deleting TrapsTo delete a trap from an SNMP community, perform the following procedure:1. From

Strany 17 -  Save Configuration

113Chapter 9IGMP SnoopingThis chapter contains the following procedures for working with IGMP Snooping in the web interface. Sections in the chapter i

Strany 18 - Web Browser Tools

Chapter 9: IGMP Snooping114OverviewIGMP enables IPv4 routers to create lists of nodes that are members of multicast groups. (A multicast group is a gr

Strany 19

AT-S101 Management Software User’s Guide115Without IGMP snooping, a switch would have to flood multicast packets from all of its ports, except the por

Strany 20

Chapter 9: IGMP Snooping116Configuring IGMP SnoopingThis procedure explains how to set IGMP snooping on the switch and set the IGMP Snooping age-out t

Strany 21 - Basic Switch Parameters

AT-S101 Management Software User’s Guide117NoteThe Multicast Group Address table contains MAC addresses of nodes that are members of multicast groups.

Strany 22

Chapter 9: IGMP Snooping1187. From the menu on the left side of the page, select Save Configuration to Flash to save your changes.

Strany 23

119Chapter 10Bandwidth ControlThis chapter contains a description of the bandwidth features and the procedure for configuring them. This chapter inclu

Strany 24 - Setting Up the IP Access List

Preface12Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support as well as sales and corporate inform

Strany 25

Chapter 10: Bandwidth Control120OverviewThe bandwidth control feature allows you regulate the reception rate of broadcast, multicast, and destination

Strany 26 - Deleting an IP

AT-S101 Management Software User’s Guide121Setting Bandwidth ControlThis procedure explains how to set DLF, broadcast, multicast, and threshold levels

Strany 27

Chapter 10: Bandwidth Control122The default is Disable. You can use the option next to the ALL row to set all of the ports to the same setting.5. To e

Strany 28

123Chapter 11Port MirroringThis chapter contains the procedure for setting up port mirroring. Port mirroring allows you to unobtrusively monitor the i

Strany 29

Chapter 11: Port Mirroring124OverviewThe port mirroring feature allows you to unobtrusively monitor the traffic received and transmitted on one or mor

Strany 30

AT-S101 Management Software User’s Guide125Configuring Port MirroringTo set up port mirroring, perform the following procedure:1. Select the Bridge fo

Strany 31 - Information

Chapter 11: Port Mirroring126Disabling Port MirroringTo disable port mirroring, perform the following procedure:1. Select the Bridge folder.The Bridge

Strany 32 - Modifying

127Chapter 12Static Multicast MAC AddressThis chapter contains a description of the static multicast MAC address feature and the procedure for configu

Strany 33 - Deleting

Chapter 12: Static Multicast MAC Address128OverviewThe AT-GS950/8POE switch has a MAC address table with a storage capacity of 8,000 entries. The tabl

Strany 34

AT-S101 Management Software User’s Guide129Setting a Static Multicast AddressThis procedure explains how to set the static multicast feature for each

Strany 35

13Chapter 1Starting a Web Browser Management SessionThis chapter contains the procedures for starting, using, and quitting a web browser management se

Strany 36 - Viewing System Information

Chapter 12: Static Multicast MAC Address130NoteThe Group MAC Address values that you enter on the Static Multicast Address Table Page are also display

Strany 37

AT-S101 Management Software User’s Guide131Modifying a Static Multicast AddressTo modify the port assignment of a multicast MAC address in the MAC add

Strany 38

Chapter 12: Static Multicast MAC Address132Deleting a Static Multicast AddressTo delete a multicast MAC address from the MAC address table, perform th

Strany 39 - Rebooting a Switch

133Chapter 13Spanning Tree and Rapid Spanning Tree ProtocolsThis chapter provides background information about the Spanning Tree Protocol (STP) and th

Strany 40

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols134OverviewThe performance of a Ethernet network can be negatively impacted by the formatio

Strany 41 - Pinging a Remote System

AT-S101 Management Software User’s Guide135Bridge Priority and the Root BridgeThe first task that bridges perform when a spanning tree protocol is act

Strany 42

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols136Path Costs andPort CostsAfter the root bridge has been selected, the bridges determine i

Strany 43 - Average Time

AT-S101 Management Software User’s Guide1373 48 11 1764 64121925 80132086 96142247 112 15 240Table 3. Port Priority Value Increments (Continued)Increm

Strany 44

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols138Forwarding Delay and Topology ChangesIf there is a change in the network topology due to

Strany 45 - Virtual LANs

AT-S101 Management Software User’s Guide139seconds and the default is two seconds. Consequently, if the AT-GS950/8POE switch is selected as the root b

Strany 46 - VLAN Overview

Chapter 1: Starting a Web Browser Management Session14Establishing a Remote Connection to the Web Browser InterfaceThe AT-GS950/8POE switch is shipped

Strany 47

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols140switch. The port is connected to an Ethernet hub, which in turn is connected to a series

Strany 48 - Tagged VLAN

AT-S101 Management Software User’s Guide141Figure 43. Point-to-Point and Edge PortDetermining whether a bridge port is point-to-point, edge, or both,

Strany 49 - Port VLAN Identifier

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols142Mixed STP and RSTP NetworksRSTP IEEE 802.1w is fully compliant with STP IEEE 802.1d. You

Strany 50 - Chapter 3: Virtual LANs

AT-S101 Management Software User’s Guide143Spanning Tree and VLANsThe spanning tree implementation in the AT-S101 Management Software is a single-inst

Strany 51 - Creating a Tagged VLAN

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols144You can avoid this problem by not activating spanning tree or by connecting VLANs using

Strany 52

AT-S101 Management Software User’s Guide145Basic STP and RSTP ConfigurationTo configure the basic STP and RSTP settings, perform the following procedu

Strany 53 - Modifying a Tagged VLAN

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols146The RSTP Configuration page allows you to configure RSTP as well as to view the current

Strany 54

AT-S101 Management Software User’s Guide147Maximum AgeThe maximum amount of time that BPDUs are stored before being deleted on the root bridge.Forward

Strany 55 - Deleting a Tagged VLAN

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols148Configuring RSTP Port SettingsThis section contains the following topics: “Configuring

Strany 56 - Creating a Port-Based VLAN

AT-S101 Management Software User’s Guide149Link StatusIndicates if the port is connected to (Up) or disconnected from (Down) another network device.Po

Strany 57 - Modifying a Port-Based VLAN

AT-S101 Management Software User’s Guide15The AT-S101 Management Software displays the login dialog box, shown in Figure 2.Figure 2. AT-S101 Login Dia

Strany 58

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols1508. In the Priority column for the port you want to configure, type a number for the port

Strany 59 - Deleting a Port-Based VLAN

AT-S101 Management Software User’s Guide151The RSTP Advanced Port Configuration Page is shown in Figure 47.Figure 47. RSTP Advanced Port Configuration

Strany 60

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols152incoming BPDUs that indicate the port should return to the blocking state to prevent a l

Strany 61 - Quality of Service (QoS)

AT-S101 Management Software User’s Guide1538. To configure all of the ports to the same settings, in the All row, configure one, two, or all of the fo

Strany 62

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols154Viewing the Spanning Tree TopologyTo view the current spanning tree topology, perform th

Strany 63

AT-S101 Management Software User’s Guide155Designated BridgeAn adjacent bridge to which the root port of the switch is actively connected.Designated P

Strany 64

Chapter 13: Spanning Tree and Rapid Spanning Tree Protocols156

Strany 65

157Chapter 14802.1x Port-based Network Access ControlThis chapter contains information about the 802.1x Port-based Network Access Control feature. Thi

Strany 66

Chapter 14: 802.1x Port-based Network Access Control158Overview802.1x Port-based Network Access Control (IEEE 802.1x) is used to control who can send

Strany 67 - Configuring CoS

AT-S101 Management Software User’s Guide159AuthenticationProcessBelow is a brief overview of the authentication process that occurs between a supplica

Strany 68

Chapter 1: Starting a Web Browser Management Session16To change the user name and password, refer to “Configuring System Management Information” on pa

Strany 69

Chapter 14: 802.1x Port-based Network Access Control160 Force-unauthorized - Places the port in the unauthorized state, ignoring all attempts by the

Strany 70

AT-S101 Management Software User’s Guide161node is the RADIUS authentication server. Since the server cannot authenticate itself, its port must be set

Strany 71 - Port Configuration

Chapter 14: 802.1x Port-based Network Access Control162 The authentication server must be a member of the Default VLAN by communicating with the swit

Strany 72

AT-S101 Management Software User’s Guide163Figure 50. Port-based Authentication Across Multiple Switches1371AT-GS950/8POE8 Port 10/100/1000Mbps + 2 SF

Strany 73

Chapter 14: 802.1x Port-based Network Access Control164Guest VLANsAn authenticator port in the unauthorized state typically accepts and transmits only

Strany 74 - Chapter 5: Port Configuration

AT-S101 Management Software User’s Guide165Configuring 802.1x Port-based Network Access ControlTo configure 802.1x port-based network access control,

Strany 75

Chapter 14: 802.1x Port-based Network Access Control1664. Configure the following parameters as needed. The parameters are defined here:NAS IDThis par

Strany 76

AT-S101 Management Software User’s Guide167Quiet PeriodSets the number of seconds that the port remains in the quiet state following a failed authenti

Strany 77 - Port Trunking

Chapter 14: 802.1x Port-based Network Access Control168authentication port in the single operating mode. Choose a value between 0 and 4,000. Then clic

Strany 78 - Port Trunking Overview

169Chapter 15RADIUS Authentication ProtocolThis chapter explains how to configure the RADIUS client on the switch. You can use the RADIUS client with

Strany 79 - Static Port Trunk Guidelines

AT-S101 Management Software User’s Guide17 Tools Save Configuration4. To see the front panel of the switch, select Front Panel from the menu on the

Strany 80 - Creating a Port Trunk

Chapter 15: RADIUS Authentication Protocol170OverviewRADIUS (Remote Authentication Dial In User Services) is an authentication protocol for enhancing

Strany 81

AT-S101 Management Software User’s Guide171Configuring the RADIUS ClientTo configure the RADIUS client, perform the following procedure:1. From the me

Strany 82 - Modifying a Port Trunk

Chapter 15: RADIUS Authentication Protocol172

Strany 83 - 7. Click Apply

173Chapter 16Destination MAC FilterThis chapter contains an explanation of the Destination MAC Filter feature as well a procedure for configuring it.

Strany 84 - Disabling a Port Trunk

Chapter 16: Destination MAC Filter174OverviewThe Destination MAC Filter feature prevents the AT-GS950/8POE switch from forwarding packets to a specifi

Strany 85 - LACP Port Trunks

AT-S101 Management Software User’s Guide175Configuring a Destination MAC FilterTo set MAC address in the Destination MAC Filter, perform the following

Strany 86 - LACP Overview

Chapter 16: Destination MAC Filter1764. From the menu on the left side of the page, select Save Configuration to Flash to save your changes.

Strany 87

AT-S101 Management Software User’s Guide177Deleting a Destination MAC FilterTo delete a MAC address from the Destination MAC Filter, perform the follo

Strany 88 - Chapter 7: LACP Port Trunks

Chapter 16: Destination MAC Filter178

Strany 89

179Chapter 17Power over Ethernet (PoE)This chapter contains a description of the Power over Ethernet (PoE) feature and the procedure for configuring i

Strany 90 - LACP Port Priority Value

Chapter 1: Starting a Web Browser Management Session18Web Browser ToolsYou can use the web browser tools to move around the management pages. Selectin

Strany 91

Chapter 17: Power over Ethernet (PoE)180OverviewThe four of the twisted pair ports on the AT-GS950/8POE switch feature Power over Ethernet (PoE) which

Strany 92

AT-S101 Management Software User’s Guide181Power Budgeting The AT-GS950/8POE switch provides a maximum of 15.4 W of power per port on four of the eigh

Strany 93

Chapter 17: Power over Ethernet (PoE)182Setting Power over EthernetThis procedure explains how to set the POE feature on the AT-GS950/8POE switch.To s

Strany 94 - Displaying LACP Group Status

AT-S101 Management Software User’s Guide1833. To change the setting of the Priority field, use the pull-down menu to select one of the following power

Strany 95

Chapter 17: Power over Ethernet (PoE)184

Strany 96 - Selecting Port Priority

185Chapter 18ClassifiersThis chapter explains the concepts of classifiers which are used to describe traffic flow for Access Control Policies. A proce

Strany 97

Chapter 18: Classifiers186OverviewA classifier defines a traffic flow which consists of packets that share one or more characteristics. You can define

Strany 98

AT-S101 Management Software Features Guide187Classifier CriteriaThe components of a classifier are defined in the following subsections.Source MAC Add

Strany 99 - Chapter 8

Chapter 18: Classifiers188Figure 56. User Priority and VLAN Fields within an Ethernet FrameYou can identify a traffic flow of tagged packets using the

Strany 100 - SNMP Overview

AT-S101 Management Software Features Guide189Observe the following guidelines when using this variable: When selecting a Layer 4 variable, this varia

Strany 101 - Community String Attributes

AT-S101 Management Software User’s Guide19Quitting a Web Browser Management SessionTo exit a web browser management session, close the web browser.

Strany 102

Chapter 18: Classifiers190 IGMP IP protocol numberIf you choose to specify the protocol by its number, you can enter the value in decimal or hexadec

Strany 103

AT-S101 Management Software Features Guide191GuidelinesFollow these guidelines when creating a classifier: Each classifier represents a separate traf

Strany 104 - Creating an SNMP Community

Chapter 18: Classifiers192Creating ClassifiersTo create a classifier, perform the following procedure:1. From the menu on the left side of the page, s

Strany 105 - Modifying an SNMP Community

AT-S101 Management Software Features Guide1933. Input the following fields:Classifier IndexIndicates the identification number of the classifier. You

Strany 106 - Deleting an SNMP Community

Chapter 18: Classifiers194Source Layer 4 PortSpecify a source port number in TCP or UDP to filter. See “Source Ports (Layer 4) Destination Ports (Laye

Strany 107 - Creating a Host Table

195Chapter 19Access Control PoliciesThis chapter describes access control policies (ACP) and how they can improve network security and performance. Th

Strany 108 - Modifying a Host Table Entry

Chapter 19: Access Control Policies196OverviewAn access control policy is a filter that controls the ingress traffic on a port. It defines a category

Strany 109 - Deleting a Host Table Entry

AT-S101 Management Software User’s Guide197ACP ComponentsIn order to create a policy, you must define the ACP components. A policy must contain a clas

Strany 110 - Enabling or Disabling Traps

Chapter 19: Access Control Policies198GuidelinesHere are guidelines for creating ACPs: A port can have multiple permit and deny ACPs. An ACP must ha

Strany 111 - Modifying Traps

AT-S101 Management Software User’s Guide199Creating Profile ActionThe procedure in this section allows you to create a profile action for DSCP and CoS

Strany 112 - Deleting Traps

Copyright 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Te

Strany 113 - IGMP Snooping

Chapter 1: Starting a Web Browser Management Session20

Strany 114 - Overview

Chapter 19: Access Control Policies2005. To set the policied CoS value for this profile, select a value between 0 and 7 in the Policied-CoS field.6. C

Strany 115

AT-S101 Management Software User’s Guide201Creating an In-profile ActionThe In-profile Action Page allows you to assign an action to a policy. For mor

Strany 116 - Configuring IGMP Snooping

Chapter 19: Access Control Policies2026. Then click Apply to activate your changes.The In-profile Action table is updated.7. From the menu on the left

Strany 117

AT-S101 Management Software User’s Guide203Creating an Out-Profile ActionThe Out-profile Action Page allows you to assign a classifier index to a prof

Strany 118 - Chapter 9: IGMP Snooping

Chapter 19: Access Control Policies2045. Enter a committed rate between 1 and 1,000 Megabits per second.6. Enter a burst size which is the maximum amo

Strany 119 - Bandwidth Control

AT-S101 Management Software User’s Guide205Creating an Access Control Port ListThis section provides a procedure to assign an index to a list of ports

Strany 120

Chapter 19: Access Control Policies206Creating a PolicyThis section provides a procedure to create a policy. For information about classifiers, see “C

Strany 121 - Setting Bandwidth Control

AT-S101 Management Software User’s Guide207Classifier IndexSpecific the identification number of a classifier. You must assign a classifier that you c

Strany 122 - Chapter 10: Bandwidth Control

Chapter 19: Access Control Policies208Displaying a Policy SequenceTo create a policy sequence, perform the following procedure:1. From the menu on the

Strany 123 - Port Mirroring

209Chapter 20Management Software UpdatesThis chapter explains the methods for upgrading the AT-S101 Management Software on the switch and saving confi

Strany 124

21Chapter 2Basic Switch ParametersThis chapter provides procedures to perform basic switch activities such as reassigning the IP address, enabling the

Strany 125 - Configuring Port Mirroring

Chapter 20: Management Software Updates210OverviewYou can use the Management Software Updates features to upgrade the AT-S101 Management Software to a

Strany 126 - Disabling Port Mirroring

AT-S101 Management Software User’s Guide211Upgrading a Firmware Image Using HTTPThis section describes how to upgrade an firmware image of the AT-S101

Strany 127 - Static Multicast MAC Address

Chapter 20: Management Software Updates212The Firmware Upgrade via HTTP Page is displayed. See Figure 65.Figure 65. Firmware Upgrade via HTTP Page3. C

Strany 128

AT-S101 Management Software User’s Guide213Upgrading a Firmware Image Using TFTPThis section describes how to upgrade an firmware image of the AT-S101

Strany 129

Chapter 20: Management Software Updates214The Firmware Upgrade via TFTP page is shown in Figure 66.Figure 66. Firmware Upgrade via TFTP PageThe Image/

Strany 130

AT-S101 Management Software User’s Guide215Downloading or Uploading a Configuration File via HTTPThis section describes how to download or upload a co

Strany 131

Chapter 20: Management Software Updates2164. Change the following parameters as necessary:Select File:Enter the path of the firmware file or click the

Strany 132

AT-S101 Management Software User’s Guide217Downloading or Uploading a Configuration File via TFTPThis section describes how to download or upload a co

Strany 133 - Protocols

Chapter 20: Management Software Updates2184. Change the following parameters as necessary:Enter the IP address of the TFTP server in the field next to

Strany 134

219Chapter 21StatisticsThe sections in this chapter explain how to display traffic, error, and history statistics about the AT-GS950/8POE switch and i

Strany 135

Chapter 2: Basic Switch Parameters22Configuring an IP Address, Subnet Mask and Gateway AddressThis procedure explains how to change the IP address, su

Strany 136 - Port Costs

Chapter 21: Statistics220OverviewStatistics provide important information for troubleshooting switch problems at the port level. The AT-S101 Managemen

Strany 137

AT-S101 Management Software User’s Guide221Displaying Traffic Comparison StatisticsTo display traffic comparison statistics, perform the following pro

Strany 138 - Data Units

Chapter 21: Statistics2223. To view traffic statistics, click on the arrow next to “Statistics” and select one of the options in Table 6.Table 6 Traf

Strany 139 - (Full-duplex Mode)

AT-S101 Management Software User’s Guide2234. To select the amount of time before the screen is refreshed, click Auto Refresh. Choose from the followi

Strany 140 - Edge Port

Chapter 21: Statistics224– Yellow – Orange– Gray– Light Red– Light Blue– Light Green– Light Yellow– Light Gray6. To create the traffic comparis

Strany 141 - Workstation

AT-S101 Management Software User’s Guide225Displaying Error Group StatisticsTo display error group statistics for a port, perform the following proced

Strany 142 - Mixed STP and RSTP Networks

Chapter 21: Statistics2264. To select the amount of time before the screen is refreshed, click Auto Refresh. Choose from the following options:– 5 se

Strany 143 - Spanning Tree and VLANs

AT-S101 Management Software User’s Guide227Displaying Historical Status ChartsTo display historical status charts statistics for a port, perform the f

Strany 144

Chapter 21: Statistics2283. To view historical statistics, click on the arrow next to “Statistics” and select one of the options in Table 7.4. To sele

Strany 145

AT-S101 Management Software User’s Guide229– 15 seconds– 30 seconds5. To select the color of the traffic comparison graph, select Color. Choose one

Strany 146

AT-S101 Management Software User’s Guide233. Change the IP configuration parameters by entering new information in the following fields:System MAC Add

Strany 147

Chapter 21: Statistics230

Strany 148 - Settings

231Appendix AAT-S101 Management Software Default SettingsTable 8 lists the factory default settings for the management software.Table 8. AT-S101 Defau

Strany 149

Appendix A: AT-S101 Management Software Default Settings232(Duplex) Mode Auto-NegotiationJumbo (frames) DisabledFlow Control (Full-duplex Mode) Enable

Strany 150 - Port Settings

AT-S101 Management Software User’s Guide233Hello Time 2 secondsMaximum Age20 secondsForward Delay15 secondsBridge Hello Time2 secondsBridge Maximum Ag

Strany 151

Appendix A: AT-S101 Management Software Default Settings234Power over EthernetPower budget 65 WPriority LowLimit (mW) 15400Access Control PoliciesBurs

Strany 152

235IndexNumerics802.1p priority level in classifiers 187802.1x Port-based Network Access Controlauthentication process 159authenticator port, describe

Strany 153

Index236Hhardware information 36IIEEE 802.1D standard 133IEEE 802.1p standard 62IGMP snoopingconfiguring 116described 114Internet Group Management Pro

Strany 154

AT-S101 Management Software User’s Guide237topology 154rebooting the switch 39remote management sessionquitting 19starting 14root bridge 135SSNMPcreat

Strany 155

Index238

Strany 156

Chapter 2: Basic Switch Parameters24Setting Up the IP Access ListThe IP Access List feature, when enabled, restricts remote access to management softw

Strany 157 - Chapter 14

AT-S101 Management Software User’s Guide253. To set the IP restriction status, select Disable or Enable in the pull-down menu next to the IP Restricti

Strany 158

Chapter 2: Basic Switch Parameters26Deleting an IPAddressTo delete an IP address from the IP Access List, perform the following procedure:1. From the

Strany 159 - Authenticator

AT-S101 Management Software User’s Guide27Enabling and Disabling the DHCP ClientSince the AT-GS950/8POE switch is a web-only switch and does not have

Strany 160 - AT-GS950/8POE

Chapter 2: Basic Switch Parameters283. From the pull-down menu next to the DHCP Mode field, select Enable or Disable.By default, this field is set to

Strany 161 - Guidelines

AT-S101 Management Software User’s Guide29Configuring System Management InformationThis section explains how to assign a name to the switch, as well a

Strany 162

3ContentsPreface ...

Strany 163 - Switch B

Chapter 2: Basic Switch Parameters30NoteAllied Telesis recommends that you assign a name to the switch. A name can help you identify the switch when y

Strany 164 - Guest VLANs

AT-S101 Management Software User’s Guide31Configuring System Administration InformationThis section explains how to enable password protection and cre

Strany 165

Chapter 2: Basic Switch Parameters324. To create an entry number, type 1 through 8 in the box next to the Entry number field.This value appears as the

Strany 166

AT-S101 Management Software User’s Guide33The Modify Administration Page is displayed. See Figure 9.Figure 9. Modify Administration Page4. To change a

Strany 167

Chapter 2: Basic Switch Parameters34Setting the User Interface ConfigurationThis procedure explains how to adjust the user interface and security feat

Strany 168

AT-S101 Management Software User’s Guide354. To enable or disable the web server, do the following:a. Click the Web Server parameter and choose Enable

Strany 169 - Chapter 15

Chapter 2: Basic Switch Parameters36Viewing System InformationTo view general information about the switch, perform the following procedure:1. From th

Strany 170

AT-S101 Management Software User’s Guide37The Switch Information Page displays the following information:System Up ForThe number of days, hours, and m

Strany 171 - Configuring the RADIUS Client

Chapter 2: Basic Switch Parameters38subnet mask or “Enabling and Disabling the DHCP Client” on page 27 to activate the DHCP client.Default GatewayDefa

Strany 172

AT-S101 Management Software User’s Guide39Rebooting a SwitchThis procedure reboots the switch and reloads the AT-S101 Management Software from flash m

Strany 173 - Destination MAC Filter

Contents4Chapter 5: Port Configuration ...

Strany 174

Chapter 2: Basic Switch Parameters40NoteTwo additional Reboot Type options, Factory Default and Reset to Factory Default Except IP Address, are descri

Strany 175

AT-S101 Management Software User’s Guide41Pinging a Remote SystemThis procedure instructs the switch to ping a node on your network. This procedure is

Strany 176

Chapter 2: Basic Switch Parameters42Timeout ValueSpecifies the length of time, in seconds, the switch waits for a response before assuming that a ping

Strany 177

AT-S101 Management Software User’s Guide43Average TimeIndicates the time, in milliseconds, the ping was received.6. Click Back to Ping Test to return

Strany 178

Chapter 2: Basic Switch Parameters44Returning the AT-S101 Management Software to the Factory Default ValuesThis procedure returns all AT-S101 Manageme

Strany 179 - Power over Ethernet (PoE)

45Chapter 3Virtual LANsThis chapter contains a description of Virtual Local Area Networks (VLANs) and procedures for creating, modifying, and deleting

Strany 180

Chapter 3: Virtual LANs46VLAN OverviewA VLAN is a group of ports on an Ethernet switch that form a logical Ethernet segment. The ports of a VLAN form

Strany 181 - Port Power Priority

AT-S101 Management Software User’s Guide47can change the VLAN memberships through the management software without moving the workstations physically o

Strany 182 - Setting Power over Ethernet

Chapter 3: Virtual LANs48Each port of a port-based VLAN can belong to as many VLANs as needed. Therefore, traffic can be forwarded to the members of t

Strany 183

AT-S101 Management Software User’s Guide49Tagged and Untagged PortsWhen you specify that a port is a member of a tagged VLAN, you need to specify that

Strany 184

AT-S101 Management Software User’s Guide5Port Priority...

Strany 185 - Classifiers

Chapter 3: Virtual LANs50Displaying Ports and Assigning Ports to a VLANBy default, all of the ports on the switch are assigned to the Tagged VLAN. The

Strany 186

AT-S101 Management Software User’s Guide51Creating a Tagged VLANTo create a tagged VLAN, perform the following procedure:1. From the menu on the left

Strany 187 - Classifier Criteria

Chapter 3: Virtual LANs52For an example of Tagged VLANs, see Figure 17.Figure 17. Example of Tagged VLAN Page7. From the menu on the left side of the

Strany 188 - Protocol (Layer 2)

AT-S101 Management Software User’s Guide53Modifying a Tagged VLANTo modify the name or port assignments of a tagged VLAN, perform the following proced

Strany 189 - Protocol

Chapter 3: Virtual LANs546. To change the name of the VLAN, type in a name in the VLAN Name field.7. To assign ports to the VLAN, click on the port nu

Strany 190

AT-S101 Management Software User’s Guide55Deleting a Tagged VLANTo delete a tagged VLAN, perform the following procedure:1. From the menu on the left

Strany 191

Chapter 3: Virtual LANs56Creating a Port-Based VLANTo create a port-based VLAN, perform the following procedure:1. From the menu on the left side of t

Strany 192 - Creating Classifiers

AT-S101 Management Software User’s Guide57Modifying a Port-Based VLANTo modify the name or port assignments of a port-based VLAN, perform the followin

Strany 193

Chapter 3: Virtual LANs587. From the menu on the left side of the page, select Save Configuration to Flash to save your changes.

Strany 194 - Chapter 18: Classifiers

AT-S101 Management Software User’s Guide59Deleting a Port-Based VLANTo delete a port-based VLAN, perform the following procedure:1. From the menu on t

Strany 195 - Access Control Policies

Contents6Displaying Error Group Statistics...

Strany 196

Chapter 3: Virtual LANs60

Strany 197 - ACP Components

61Chapter 4Quality of Service (QoS)This chapter contains a description of the QoS feature and the procedures for configuring Quality of Service (QoS).

Strany 198

Chapter 4: Quality of Service (QoS)62OverviewWhen a port on an Ethernet switch becomes oversubscribed—its egress queues contain more packets than the

Strany 199 - Creating Profile Action

AT-S101 Management Software User’s Guide63For example, a tagged packet with a priority tag of 6 is placed in the egress port’s highest priority queue

Strany 200

Chapter 4: Quality of Service (QoS)64One last thing to note is that the CoS feature does not change the priority level in a tagged packet. The packet

Strany 201 - Creating an In-profile Action

AT-S101 Management Software User’s Guide65Mapping CoS Priorities to Egress QueuesThis procedure explains how to change the default mappings of CoS pri

Strany 202

Chapter 4: Quality of Service (QoS)66For example, to direct all tagged traffic with a traffic class of 4 to egress queue 3 on the ports, click the dia

Strany 203

AT-S101 Management Software User’s Guide67Configuring CoSAs explained in “Overview” on page 62, a packet received by a port is placed it into one of f

Strany 204

Chapter 4: Quality of Service (QoS)68The columns in the menu display the following information:Port IndexDisplays the port number. The All value refer

Strany 205

AT-S101 Management Software User’s Guide69NoteThe tagged information in a frame is not changed as the frame traverses the switch. A tagged frame leave

Strany 206 - Creating a Policy

7FiguresFigure 1: Entering a Switch’s IP Address in the URL Field...

Strany 207

Chapter 4: Quality of Service (QoS)70

Strany 208 - Displaying a Policy Sequence

71Chapter 5Port ConfigurationThis chapter provides a description of the physical characteristics of the ports and a procedure that explains how to vie

Strany 209 - Management Software Updates

Chapter 5: Port Configuration72OverviewThis chapter describes how to display and modify the physical characteristics of an AT-GS950/8POE switch. You c

Strany 210

AT-S101 Management Software User’s Guide73Displaying and Configuring Ports Using the Port Configuration PageThis procedure explains how to configure t

Strany 211

Chapter 5: Port Configuration74that the port has been added to a trunk. For information about configuring a trunk, refer to Chapter 6, “Port Trunking”

Strany 212

AT-S101 Management Software User’s Guide7510/Full - 10 Mbps in full-duplex mode100/Half - 100 Mbps in half-duplex mode10/Half - 10 Mbps in half-duplex

Strany 213

Chapter 5: Port Configuration76

Strany 214

77Chapter 6Port TrunkingThis chapter contains the following procedures for working with port trunking: “Port Trunking Overview” on page 78 “Creating

Strany 215

Chapter 6: Port Trunking78Port Trunking OverviewA port trunk is an economical way for you to increase the bandwidth between the Ethernet switch and an

Strany 216

AT-S101 Management Software User’s Guide79manufacturer. For this reason static trunks are typically employed only between devices from the same vendor

Strany 217

Figures8Figure 51: 802.1x Access Control Configuration Page...

Strany 218

Chapter 6: Port Trunking80Creating a Port TrunkThis procedure explains how to create a port trunk.CautionDo not connect the cables of a port trunk to

Strany 219 - Statistics

AT-S101 Management Software User’s Guide814. Click the dialog boxes of the ports that will make up the port trunk. A check in a box indicates the port

Strany 220

Chapter 6: Port Trunking82Modifying a Port TrunkThis procedure explains how to change the status of a port trunk and add or remove ports from a port t

Strany 221

AT-S101 Management Software User’s Guide837. Click Apply.8. Modify the port trunk on the other switch and reconnect the cables.9. From the menu on the

Strany 222 - Chapter 21: Statistics

Chapter 6: Port Trunking84Disabling a Port TrunkThis procedure explains how to disable a port trunk. NoteBefore you disable a port trunk, disconnect a

Strany 223

85Chapter 7LACP Port TrunksThis chapter contains overview information about LACP port trunks and the procedures for setting this feature. This chapter

Strany 224

Chapter 7: LACP Port Trunks86LACP OverviewLACP (Link Aggregation Control Protocol) port trunks perform the same function as static trunks. They increa

Strany 225

AT-S101 Management Software User’s Guide87If there will be more than one aggregate trunk on a switch, each trunk may require a separate aggregator or

Strany 226

Chapter 7: LACP Port Trunks88Here is how the example looks in a table format.CautionThe example cited here illustrates a loop in a network. Avoid netw

Strany 227

AT-S101 Management Software User’s Guide89Here is how this example looks in table format.You could, if you wanted, create separate aggregators for the

Strany 228

9PrefaceThe AT-S101 Management Software is the operating system for the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. This guide explains how to use

Strany 229

Chapter 7: LACP Port Trunks90LACP System PriorityIt is possible for two devices interconnected by an aggregate trunk to encounter a conflict when they

Strany 230

AT-S101 Management Software User’s Guide91The selection of the active links in an aggregate trunk is dynamic and changes as links are added, removed,

Strany 231

Chapter 7: LACP Port Trunks92GuidelinesThe following guidelines apply to creating aggregators: LACP must be activated on both the switch and the othe

Strany 232

AT-S101 Management Software User’s Guide93a higher system LACP priority than the AT-GS950/8POE switch. This can help avoid a conflict between the devi

Strany 233

Chapter 7: LACP Port Trunks94Displaying LACP Group StatusTo display the LACP Group Status, perform the following procedure:1. Select the Bridge folder

Strany 234

AT-S101 Management Software User’s Guide95The System ID is a MAC address value assigned to the switch. You cannot change this value.Key 1 - Key 4Indic

Strany 235

Chapter 7: LACP Port Trunks96Selecting Port PriorityTo select port priority, perform the following procedure:1. Select the Bridge folder.The Bridge fo

Strany 236

AT-S101 Management Software User’s Guide974. To set the port priority, select a value from 0 to 255 in the Priority column for the port you want to al

Strany 237

Chapter 7: LACP Port Trunks98

Strany 238

99Chapter 8Simple Network Management Protocol (SNMP)This chapter contains a description of SNMP and procedures for working with this protocol. This ch