Allied-telesis AT-S101 Uživatelský manuál Strana 198

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 238
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 197
Chapter 19: Access Control Policies
198
Guidelines
Here are guidelines for creating ACPs:
A port can have multiple permit and deny ACPs.
An ACP must have at least one classifier.
You can assign an ACP to more than one port.
An ACP filters ingress traffic, but not egress traffic.
The action of a ACP can be either permit or deny. If a deny ACP has a
lower sequence number than a permit ACP, then the deny ACP
overrides the permit ACP.
The order in which the ACPs are added to a port is not important since
the packets are compared against all of a port’s ACPs.
Since classifiers cannot be assigned more than once to a port, ACPs
that have the same classifier cannot be assigned to the same port.
The switch can store up to 64 ACPs.
Zobrazit stránku 197
1 2 ... 193 194 195 196 197 198 199 200 201 202 203 ... 237 238

Komentáře k této Příručce

Žádné komentáře