Allied Telesis AT-2973T Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Síťové karty Allied Telesis AT-2973T. Allied Telesis AT-2973T Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 178
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Installation Guide

613-001252 Rev. DNetExtreme II Adapters1 Gigabit and 10 Gigabit Interface Cards AT-2973SX AT-2973T AT-2973T/4 AT-VNC10SInstallation Guide100ATIL/A

Strany 2

Figures10

Strany 3 - Industry Canada

Chapter 8: Setting Advanced Properties100Advanced FeaturesTable 11 lists the advanced network adapter features in Microsoft Windows that are supported

Strany 4 - Translated Safety Statements

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide101Locally Administered AddressNo value* No value* No value* No v

Strany 5 - Contents

Chapter 8: Setting Advanced Properties102Table 12 lists the advanced network adapter features in Microsoft Windows that are supported by the AT-VNC10S

Strany 6

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide103IPv4 Large Send OffloadEnabled*DisabledEnabled*DisabledEnabled

Strany 7

Chapter 8: Setting Advanced Properties104Speed and Duplex Mode1 Gb Full10 Gb Full*1 Gb Full10 Gb Full*1 Gb Full10 Gb Full*TCP Connection Offload (IPv4

Strany 8

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide105Accessing the Advanced TabTo modify the configuration properti

Strany 9

Chapter 8: Setting Advanced Properties106Figure 19. System Properties Dialog Box4. Click the Hardware tab at the top of the System Properties dialog b

Strany 10

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide107Figure 20. System Properties Hardware Tab5. Click the Device M

Strany 11

Chapter 8: Setting Advanced Properties108Figure 21. Device Manager Window6. Double-click on the Network adapters option.

Strany 12

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide1097. In the Broadcom network adapter window, click the Advanced

Strany 13

11TablesTable 1: Network Adapter Cards ...

Strany 14

Chapter 8: Setting Advanced Properties110Selecting the Advanced Tab in Windows Server 2008, Windows Server 2008 R2, and Windows 7To select the Advance

Strany 15

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide111Figure 24. Device Manager Window3. Open the Network Adapters f

Strany 16 - Contacting Allied Telesis

Chapter 8: Setting Advanced Properties112Selecting the Advanced Tab in Windows Vista In the Windows Vista Operating System, you access the Advanced Ta

Strany 17 - Chapter 1

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide1133. Enter the following command in the Run window:mmc compmgmt.

Strany 18 - Functional Descriptions

Chapter 8: Setting Advanced Properties114Modifying the Advanced PropertiesAfter you have installed the driver software, you can use Table 13 to verify

Strany 19 - ACT LNK

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide115Flow Control Enables or disables the receipt or transmission o

Strany 20

Chapter 8: Setting Advanced Properties116IPv4 Large Send OffloadNormally, the TCP segmentation is done by the protocol stack. When you enable the Larg

Strany 21

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide117Jumbo Packet Enables the network adapter to transmit and recei

Strany 22 - AT-2973T/4

Chapter 8: Setting Advanced Properties118Number of RSS QueuesAllows configuring RSS queues. For 1 Gbps network adapters, the RSS queue options are Aut

Strany 23 - AT-VNC10S

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide119Receive Buffers(0=Auto)The number of receive buffers. Receive

Strany 24

Tables12

Strany 25

Chapter 8: Setting Advanced Properties120TCP Connection Offload (IPv4)Enables and disables TOE offload when using the IPv4 protocol. The default is En

Strany 26 - Features

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide121VLAN ID Enables VLAN tagging and configures the VLAN ID when P

Strany 27 -  IEEE Std 802.3ad teaming

Chapter 8: Setting Advanced Properties122A properly configured network that has multiple VLANs should maintain separate IP segments for each VLAN. Thi

Strany 28

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide123VMQ Lookahead SplitThe VMQ Lookahead Split property defines wh

Strany 29 - Chapter 2

Chapter 8: Setting Advanced Properties124

Strany 30 -  Standard bracket

125Chapter 9Installing CIM and SNMP for ManageabilityBoth Common Information Model (CIM) and Simple Network Management Protocol (SNMP) are information

Strany 31 - Reviewing Safety Precautions

Chapter 9: Installing CIM and SNMP for Manageability126Installing CIMThe Common Information Model (CIM) is an industry standard defined by the Distrib

Strany 32

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation Guide127SELECT * FROM __InstanceDeletionEvent where TargetInstance ISA "BRC

Strany 33

Chapter 9: Installing CIM and SNMP for Manageability128Figure 27. BACS CIM Option Window4. Select CIM Provider.5. Select one of the following: This f

Strany 34 - Pre-Installation Checklist

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation Guide129Installing SNMP The BASP version of SNMP has two components that are desc

Strany 35 - Replacing the Bracket

13PrefaceThis guide contains instructions on how to install and configure the Allied Telesis AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S adapters.T

Strany 36

Chapter 9: Installing CIM and SNMP for Manageability130The extensible-agent allows the SNMP manager software to actively monitor the configurations of

Strany 37

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation Guide1314. Select SNMP. The BACS SNMP Option Window is displayed. See Figure 27.F

Strany 38

Chapter 9: Installing CIM and SNMP for Manageability132

Strany 39

133Chapter 10Installing Management ApplicationsThis chapter provides information about prerequisites for installing management applications as well as

Strany 40

Chapter 10: Installing Management Applications134Installing Broadcom Advanced Control Suite 3 and Related Management Applications The Broadcom Advance

Strany 41

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide135Checking .NET Framework Requirements Before you use either the

Strany 42

Chapter 10: Installing Management Applications136NoteLong startup times for BACS 3 may be caused by a limitation of .NET Framework 2.0, as described i

Strany 43 - Chapter 3

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide137 “Performing a Silent Install by Feature on IA32 Platforms” o

Strany 44

Chapter 10: Installing Management Applications138NoteAfter performing a silent uninstall, it is necessary to reboot the system before reinstalling thi

Strany 45 - Configuring the

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide139Modifying Management Applications To modify the management app

Strany 46 - Setting Up the

Preface14Safety Symbols Used in this DocumentThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inf

Strany 47 - Red Hat Linux PXE Server

Chapter 10: Installing Management Applications140Repairing Management Applications To repair or reinstall the management applications, do the followin

Strany 48

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide141Removing Management Applications To remove all management appl

Strany 49 - Chapter 4

Chapter 10: Installing Management Applications142

Strany 50

143Chapter 11TroubleshootingThis chapter provides troubleshooting information. It discusses the following topics: “Checking Hardware Diagnostics” on

Strany 51

Chapter 11: Troubleshooting144Checking Hardware Diagnostics Loopback diagnostic tests are available for testing the adapter hardware. These tests prov

Strany 52

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide145Checking Port LEDs To check the state of the network link and

Strany 53

Chapter 11: Troubleshooting146Consulting the Troubleshooting Checklist CautionBefore you open the cabinet of your server to add or remove the adapter,

Strany 54

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide147Linux To verify that the bnx2.o driver is loaded properly, ent

Strany 55 - Chapter 5

Chapter 11: Troubleshooting1483. If you are performing the ping command at the system where the new adapter is installed, type ipconfig /all to verify

Strany 56

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide149Solving Microsoft Windows Server 2008 R2 Hyper-V IssuesMicroso

Strany 57

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide15Where to Find Web-based GuidesThe installation and user guides

Strany 58 - Startup Disk

Chapter 11: Troubleshooting150When configuring a team of NetXtreme II network adapters on a Hyper-V system, be aware of the following:  Create the te

Strany 59 - Modifying the

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide151NoteThis does not include an unattended installation when perf

Strany 60

Chapter 11: Troubleshooting152Solving Broadcom Boot Agent and Broadcom Advanced Server Program (BASP) IssuesThis section discusses issues with the Bro

Strany 61 - Driver Software

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide153Problem: A Generic Trunking (GEC/FEC) 802.3ad-Draft Static typ

Strany 62

Chapter 11: Troubleshooting154Solving Miscellaneous IssuesThis section presents issues and provides solutions for a variety of driver software issues.

Strany 63

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide155Solution: This is a Microsoft issue. For more information, see

Strany 64

Chapter 11: Troubleshooting156

Strany 65 - Chapter 6

157Chapter 12User DiagnosticsThis chapter provides user diagnostic information for the MS-DOS platform. This chapter discusses the following topics:

Strany 66

Chapter 12: User Diagnostics158OverviewBroadcom NetXtreme II User Diagnostics is an MS-DOS based application that runs a series of diagnostic tests. T

Strany 67

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide159System Requirements The following system requirements are need

Strany 68 - Source RPM

Preface16Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support and for sales and corporate informati

Strany 69

Chapter 12: User Diagnostics160Performing Diagnostics At the MS-DOS prompt, type uxdiag followed by the command options. The uxdiag command options ar

Strany 70 - Source TAR File

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide161uxdiag -fump <ump_image> Specifies the bin file to updat

Strany 71 - Components

Chapter 12: User Diagnostics162uxdiag -ver Displays the version of Broadcom NetXtreme II User Diagnostics (uxdiag) and all installed adapters. uxdiag

Strany 72 - Linux Driver

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide163Diagnostic Test Descriptions The diagnostic tests are divided

Strany 73 - Files (Optional)

Chapter 12: User Diagnostics164Group B: Memory TestsB1 TXP ScratchpadThe Group B tests verify all of the memory blocks of the Broadcom NetXtreme II ad

Strany 74 - Installations

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide165C2 RBUF Allocation Verifies the RX buffer (RBUF) allocation i

Strany 75

Chapter 12: User Diagnostics166C8 DMA Engine Verifies the functionality of the DMA engine block by performing numerous DMA read and write operations

Strany 76

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide167D2 PHY Loopback Enables PHY loopback mode in the adapter and t

Strany 77 - Messages

Chapter 12: User Diagnostics168

Strany 78

169Appendix ASpecificationsPhysical SpecificationsThis section provides the dimensions and weight of the adapters.Dimensions: AT-2973SX: 14.47 cm x 5.

Strany 79

17Chapter 1Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S AdaptersThis chapter provides an introduction to the Allied Telesis AT-2973S

Strany 80

Appendix A: Specifications170Power SpecificationsThe following power specifications apply to the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S adapt

Strany 81 - Linux iSCSI

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide17110/100/1000Base-T Twisted-Pair Port ConnectorsThis section lis

Strany 82

Appendix A: Specifications172

Strany 83

173Appendix BCleaning Fiber Optic ConnectorsThe fiber optic connector consists of a fiber optic plug and its adapter. The end of the fiber optic cable

Strany 84

Appendix B: Cleaning Fiber Optic Connectors174Using a Cartridge-Type CleanerFiber optic cartridge cleaners are available from many vendors and are typ

Strany 85

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide175NoteRub the ferrule tip on the cleaning surface in one directi

Strany 86

Appendix B: Cleaning Fiber Optic Connectors176Using a SwabSpecially treated swabs, known as stick cleaners, are available for cleaning inside connecto

Strany 87 - Chapter 7

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide1773. If a fiber inspection scope is available, use the scope to

Strany 88

Appendix B: Cleaning Fiber Optic Connectors178

Strany 89

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters18Functional DescriptionsThe AT-2973SX, AT-2973T, AT-2973T/4, and AT

Strany 90

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide19As part of the company’s green range, all four adapters are eng

Strany 91

Copyright  2011 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Strany 92

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters20Figure 2. AT-2973SX FaceplateFor AT-2973SX LED information, see Ta

Strany 93 - 4. Click Install

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide21Figure 3. AT-2973T Adapter AT-2973T Adapter Physical Descriptio

Strany 94 - Installation

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters22AT-2973T/4 AdapterThe AT-2973T/4 adapter, shown in Figure 5 on pag

Strany 95 - Performing a Silent Uninstall

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide23Figure 6. AT-2973T/4 FaceplateThe functions of the LEDs for the

Strany 96 - Performing a Silent Reinstall

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters24Figure 7. AT-VNC10S Adapter AT-VNC10S Adapter Physical Description

Strany 97 - Removing the Device Drivers

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide25The functions of the LEDs for the SFP+ slots are described in T

Strany 98

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters26Features The following list of adapter features applies to the AT-

Strany 99 - Chapter 8

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide27 Smart Load Balancing Teaming IEEE Std 802.3ad teamingTCP Off

Strany 100 - Advanced Features

Chapter 1: Introducing the AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters28Wake on LAN (WOL) FeatureThe WOL feature sets the speed at which t

Strany 101

29Chapter 2Installing the HardwareThis chapter describes how to install the AT-2973SX, AT-2973T,AT-2973T/4, and AT-VNC10S adapters in a PC and discus

Strany 102

3Electrical Safety and Emissions StandardsThis product meets the following standards.Federal Communications Commission Interference StatementDeclarati

Strany 103

Chapter 2: Installing the Hardware30Reviewing the Contents of Your ShipmentThe following items are included with your adapter:  Antistatic bag (used

Strany 104

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide31Reviewing Safety PrecautionsPlease review the following safety

Strany 105 - Accessing the Advanced Tab

Chapter 2: Installing the Hardware32WarningThe adapter is being installed in a system that operates with voltages that can be lethal. Before you remov

Strany 106

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide33Reviewing Cabling RequirementsThe cabling requirements for the

Strany 107

Chapter 2: Installing the Hardware34Pre-Installation ChecklistBefore you install an adapter card, do the following:1. Verify that your system is using

Strany 108

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide35Replacing the BracketThe AT-2973SX, AT-2973T, AT-VNC10S adapter

Strany 109 - Figure 22. Advanced Tab

Chapter 2: Installing the Hardware362. Align the tabs of the standard bracket with the holes on the adapter and fasten the screws onto the adapter. Se

Strany 110

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide37Installing a Network Adapter CardThe following instructions app

Strany 111

Chapter 2: Installing the Hardware38Figure 11. Removing the PC Cover3. Select an empty, non-shared PCIe slot and remove the faceplate. Keep the facepl

Strany 112 - Windows Vista

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide394. Remove the network adapter card from the shipping package an

Strany 113

4RFI Emissions FCC Class B, EN55022 Class B, VCCI Class B, C-TICK, CEImmunity EN55024Electrical Safety EN60950-1 (TUV), UL 60950-1 (CULUS)Translated S

Strany 114

Chapter 2: Installing the Hardware40Figure 14. Securing the Adapter with a High-profile Bracket7. Replace the system’s cover and secure it with the sc

Strany 115

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide41Installing SFP+ Transceivers in the AT-VNC10S AdapterHere are t

Strany 116

Chapter 2: Installing the Hardware42

Strany 117

43Chapter 3Installing Broadcom Boot Agent Driver SoftwareThis chapter provides information about how to install the Broadcom Boot Agent Driver Softwar

Strany 118

Chapter 3: Installing Broadcom Boot Agent Driver Software44Overview The AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S NetXtreme II Family adapters su

Strany 119

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide45Setting Up MBA in a Client Environment Setting up a Multiple Bo

Strany 120

Chapter 3: Installing Broadcom Boot Agent Driver Software46NoteThe message prompting you to press CTRL+S is displayed once for each Broadcom NetXtreme

Strany 121

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide47Setting Up MBA in a Server Environment: Red Hat Linux PXE Serve

Strany 122

Chapter 3: Installing Broadcom Boot Agent Driver Software48

Strany 123

49Chapter 4Installing the Monolithic Software DriverA monolithic driver allows you to download an image of a PC onto an image server and then to anoth

Strany 124

5ContentsPreface...

Strany 125 - Chapter 9

Chapter 4: Installing the Monolithic Software Driver50Using the NetXtreme II Monolithic DriverThe NetXtreme II Monolithic driver is used with a remote

Strany 126 - Installing CIM

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide51Inserting the NetXtreme II Monolithic Driver in a WinPE 2.0 Ima

Strany 127 - Libraries

Chapter 4: Installing the Monolithic Software Driver525. Place the monolithic driver and inf file in c:\drivers\x32\ by entering:peimg /inf=c:\Drivers

Strany 128

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide53Configuring the Speed and Duplex Settings Since the typical env

Strany 129 - Installing SNMP

Chapter 4: Installing the Monolithic Software Driver54Options for fiber interfaces: – Auto (1 Gbps is enabled when that speed is supported) = "0

Strany 130 - SNMP Libraries

55Chapter 5Installing the NDIS2 Driver SoftwareThis chapter provides procedures to install the NDIS2 driver on the Microsoft Network Client and DOS ND

Strany 131

Chapter 5: Installing the NDIS2 Driver Software56Overview The BXND20X Broadcom NetXtreme II Gigabit Ethernet driver is described in this chapter. This

Strany 132

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide57Checking Pre-installation Requirements Before you can successfu

Strany 133 - Chapter 10

Chapter 5: Installing the NDIS2 Driver Software58Installing the NDIS2 Driver Software on MS-DOS Platforms The NDIS2 driver software can be run from an

Strany 134 - Management Applications

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide597. Open the NCADMIN folder and double-click ncadmin.exe. 8. Fol

Strany 135 - Requirements

Figures6Installing the NDIS2 Driver Software on MS-DOS Platforms...

Strany 136 - Install Option

Chapter 5: Installing the NDIS2 Driver Software60DriverName=BXND20X$ [protman]DriverName=PROTMAN$PRIORITY=MS$NDISHLP[MS$NDISHLP]DriverName=ndishl

Strany 137

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide616. Create the appropriate Autoexec.bat file in drive A for the

Strany 138

Chapter 5: Installing the NDIS2 Driver Software625. Edit the Autoexec.bat file by adding the following lines: C:\LANMAN\NETBIND.EXEC:\LANMAN\NET STAR

Strany 139

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide63Using Keywords for the Drivers The Protocol.ini file contains c

Strany 140

Chapter 5: Installing the NDIS2 Driver Software64 NodeAddress. Specifies the network address used by the network adapter. If a multicast address or a

Strany 141

65Chapter 6Installing the Linux DriversThis chapter provides procedures to install the Linux drivers for the adapters.This chapter discusses the follo

Strany 142

Chapter 6: Installing the Linux Drivers66OverviewThis chapter discusses the Linux drivers for the Broadcom NetXtreme II network adapters and describes

Strany 143 - Chapter 11

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide67Broadcom iSCSI offload initiators is supported on SLES 10 SP1.

Strany 144 - Chapter 11: Troubleshooting

Chapter 6: Installing the Linux Drivers68Installing Linux Driver Software There are two ways to install the Linux driver software— from the Source RPM

Strany 145 - Checking Port LEDs

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide693. Install the newly built package which includes the driver an

Strany 146 - Current Drivers

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide7Testing Network Connectivity...

Strany 147 - Connectivity

Chapter 6: Installing the Linux Drivers70To configure the network protocol and address, refer to the documentation provided with your operating system

Strany 148

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide71Building the bnx2i Driver To build the bnx2i Linux driver from

Strany 149 - Adapters

Chapter 6: Installing the Linux Drivers72Using system service: service bnx2id stop2. Load the iSCSI driver and the user daemon. Do the following:Manua

Strany 150

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide73To unload the driver, use ifconfig to bring down all eth# inter

Strany 151

Chapter 6: Installing the Linux Drivers74cp /usr/share/hwdata/pcitable /usr/share/hwdata/old.pcitablecp /usr/share/hwdata/pcitable.new /usr/share/hwda

Strany 152 - Program (BASP) Issues

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide75Setting Optional Properties for the bnx2i Driver You can supply

Strany 153

Chapter 6: Installing the Linux Drivers76NoteBroadcom validation is limited to a power of 2; for example, 32, 64, or 128. rq_size Use the “Configure R

Strany 154 - Solving Miscellaneous Issues

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide77Checking the bnx2 Driver DefaultsThe bnx2 driver defaults to th

Strany 155

Chapter 6: Installing the Linux Drivers78Checking the bnx2 Driver MessagesThe following are the most common bnx2 driver messages:Driver Sign on Broadc

Strany 156

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide79NoteThis message is displayed only when the user attempts to ma

Strany 158 - Overview

Chapter 6: Installing the Linux Drivers80NoteChange mtu to 1500 using ifconfig and restart the interface in order to offload iSCSI connections. SCSI-M

Strany 159 - System Requirements

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide81bnx2i: iscsi_error - pend r2t in cleanupbnx2i: iscsi_error - I

Strany 160 - Performing Diagnostics

Chapter 6: Installing the Linux Drivers82 The iSCSI driver/firmware will not offload iSCSI connections onto a jumbo frame-enabled CNIC device.  For

Strany 161

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide83rpm -e open-iscsi2. Install the source RPM package by entering:

Strany 162 - Chapter 12: User Diagnostics

Chapter 6: Installing the Linux Drivers84where XPORT_NAME=bcm570x-xxyyzz xx - pci bus number of the NX2 deviceyy - pci device number of the NX2 devic

Strany 163 - Diagnostic Test Descriptions

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide85Maximizing Offload iSCSI Connections With default driver parame

Strany 164

Chapter 6: Installing the Linux Drivers86

Strany 165

87Chapter 7Installing the Windows DriversThis chapter provides procedures to install and remove the driver software for all of the Windows Operating S

Strany 166

Chapter 7: Installing the Windows Drivers88Supported Versions of Microsoft WindowsTable 10 lists the versions of Microsoft Windows supported by the ad

Strany 167

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide89Installing the Windows Driver Software This chapter describes h

Strany 168

9FiguresFigure 1. AT-2973SX Adapter ...

Strany 169 - Environmental Specifications

Chapter 7: Installing the Windows Drivers90NoteYou must physically install a network device driver before the Broadcom NetXtreme II Controller can be

Strany 170 - Operating Specifications

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide91The Broadcom NetXtreme II Driver Installer - InstallShield Wiza

Strany 171

Chapter 7: Installing the Windows Drivers92Figure 16. License Agreement Page3. After you review the license agreement, click I accept the terms in the

Strany 172 - Appendix A: Specifications

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide93Figure 17. Ready to Install the Program Page4. Click Install. T

Strany 173 - Appendix B

Chapter 7: Installing the Windows Drivers94Figure 18. InstallShield Wizard Completed Page5. Click Finish to close the wizard. 6. The installer determi

Strany 174 - PUSH OPENPUSH OPEN

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide95NoteAll commands are case sensitive. NoteUser must “Run as Admi

Strany 175

Chapter 7: Installing the Windows Drivers96To perform a silent uninstall from within the installer source folder, enter:msiexec /x "BDrv5706.msi&

Strany 176 - Using a Swab

AT-2973SX, AT-2973T, AT-2973T/4, and AT-VNC10S Adapters Installation and User’s Guide97Removing the Device DriversThis section discusses how to remove

Strany 177

Chapter 7: Installing the Windows Drivers98

Strany 178

99Chapter 8Setting Advanced PropertiesFor all of the Windows operating systems, you access the Windows Advanced Properties from the Advanced Tab. Alth

Komentáře k této Příručce

Žádné komentáře