6 Issues Resolved in Previous Releases
The heading Level refers to the level of service affected before the issue was resolved.
1: Service Disruption
2: Disruption, but Workaround
3: Inconvenience
Release PR Level Title Description
14.2.0 22064 2 GE24POE: Manual
per-port power limit is
34.7W rather than
40W
The GE24POE card hardware
is capable of providing 40W of
power to a port. However, the
firmware currently imposes a
more restrictive limit of
34.7W. This will be resolved
in a subsequent firmware
release. In 14.2.0, customer
documentation shows the
POWERLIMIT range for SET
POE INTERFACE and
ENABLE POE INTERFACE
to have a maximum of 30000.
14.2.0 21809 3 Quickly learning an
excessive volume of
MAC addresses can
lead to incomplete
FDB.
If more than 16K MAC+VID addresses are
present in the network, then events that
clear the FDB (and thus require relearning
all the addresses in a very short time) can
result in incomplete FDB population. This
is not a problem if the number of MAC
addresses is less than the system limit of
16K. This has been fixed in 14.2.0.
14.2.0 21776 3 PSU mismatch causes
erroneous PoE Power
If a System PSU is inserted in a PoE PSU
slot, then this impacts the POE available to
the POE subsystem. This will cause
“SHOW POE” command to display an
incorrect POE power total and cause the
POE threshold alarm to be raised and
cleared at incorrect times. This has been
fixed in 14.2.0. Total POE power available
won't be increased if a bad POE PSU is
inserted
14.2.0 21732 3 ENABLE EPSR on
more than 10 domains
in a single command
may cause errors
When enabling a large number of EPSR
domains with a single command, errors can
occur in the processing. Recommended
work-around is to enable domains
individually. This has been fixed in 14.2.0.
Error logs no longer occur.