613-001297 Rev. B AT-SBx3112 Chassis AT-SBx31CFC Fabric Control Card AT-SBx31XZ4 XFP Line Card AT-SBx31GP24 PoE Line Card AT-SBx3161 System Power Supp
List of Tables10
Appendix A: Technical Specifications100Environmental SpecificationsOperating Temperature: -0° C to 40° C (32° F to 104° F)Storage Temperature: -25° C
SwitchBlade x3112 Installation Guide101Safety and Electromagnetic Emissions CertificationsEMI/RFI: FCC Class A, EN55022 Class A, CISPR Class AImmunit
Appendix A: Technical Specifications102Connectors and Port PinoutsThis section lists the connectors and connector pinouts for the SwitchBlade x3112 l
SwitchBlade x3112 Installation Guide103Table 16 lists the RJ-45 connector pins and their signals when a 1000Base-T port is operating at 1000 Mbps.Tabl
Appendix A: Technical Specifications104Cable RequirementsTable 17. Cable Requirements for the 10/100/1000Base-T Management PortSpeed Cable TypeMaximum
11PrefaceThis guide provides the hardware installation instructions for your SwitchBlade x3112 switch. This preface contains the following sections:
Preface12Safety Symbols Used in this DocumentThis document uses the safety symbols defined in Table 1.Table 1. Safety SymbolsSymbol Meaning Descriptio
SwitchBlade x3112 Installation Guide13Where to Find Web-based GuidesThe installation and user guides are available for all Allied Telesis products in
Preface14Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate inform
15Chapter 1OverviewThis chapter provides descriptions of the SwitchBlade x3112 chassis, line cards, power supplies and fan tray and contains the follo
Chapter 1: Overview16IntroductionThe SwitchBlade x3112 Switch is a modular enterprise access edge chassis scalable for GB and 10G Ethernet application
SwitchBlade x3112 Installation Guide17AT-SBx3112 ChassisThe AT-SBx3112 Chassis has a modular design that is seven Rack Units (RU’s) high. It contains
Chapter 1: Overview18Figure 2 Rear View of the AT-SBx3112 ChassisAT-SBx3112 Chassis SlotsThe AT-SBx3112 Chassis has four power supply slots, 12 line
SwitchBlade x3112 Installation Guide19Table 2. AT-SBx3112 Chassis SlotsSlot Line Cards/Power SuppliesA and B These slots are for the primary and red
Copyright © 2010 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied
Chapter 1: Overview20AT-SBx31CFC Fabric Control CardThe AT-SBx31CFC Fabric Control Card provides two functions: the central switching fabric between a
SwitchBlade x3112 Installation Guide21AT-SBx31CFC Fabric Control Card FeaturesThe AT-SBx31CFC Fabric Control Card supports the following features: Su
Chapter 1: Overview22NoteAll the System Status LEDs on the inactive AT-SBx31CFC Fabric Control Card do not illuminate unless this card assumes the rol
SwitchBlade x3112 Installation Guide23SBx STATUS LEDsThe SBx STATUS LEDs on the AT-SBx31CFC Fabric Control Card display the general operating states o
Chapter 1: Overview24eco-friendly Button The eco-friendly button on the AT-SBx31CFC Fabric Control Card front panel is used to turn off the LEDs on th
SwitchBlade x3112 Installation Guide25active controller and the active controller becomes the inactive or standby controller. During this process, the
Chapter 1: Overview26pinouts, refer to “Connectors and Port Pinouts” on page 102. The default setting for the Management port is Auto-Negotiation with
SwitchBlade x3112 Installation Guide27USB Port The USB slot is an interface designed for temporary storage of configuration files on a memory stick. T
Chapter 1: Overview28SD Status LED The SD Status LED on the AT-SBx31CFC Fabric Control Card is displayed in Figure 9 on page 27 and described in Table
SwitchBlade x3112 Installation Guide29AT-SBx31GP24 PoE Line CardThe AT-SBx31GP24 PoE Line Card provides 24 10/100/1000 Base-T Ethernet switching capab
3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-
Chapter 1: Overview30Connector Type The ports are 8-pin RJ-45 connectors that use four pins at 10 or 100 Mbps and all eight pins at 1000 Mbps. For the
SwitchBlade x3112 Installation Guide31Cable Type The cabling requirements for a 10/100/1000Base-T port are: For 10 Mbps operation: Standard TIA/EIA 5
Chapter 1: Overview32Port LEDs Each port on the AT-SBx31GP24 PoE Line Card has two status LED as displayed in Figure 11 and described in Table 7.Figur
SwitchBlade x3112 Installation Guide33AT-SBx31GP24Power over EthernetThe twisted-pair ports on the AT-SBx31GP24 PoE Line Card feature Power over Ether
Chapter 1: Overview34The PoE power is supplied to the PoE ports on a first come basis. By default, the highest PoE priority starts from slot 0, port 0
SwitchBlade x3112 Installation Guide35Implementation A standard Ethernet twisted-pair cable contains four pairs of strands for a total of eight strand
Chapter 1: Overview36AT-SBx31XZ4 XFP Line Card The AT-SBx31XZ4 XFP Line Card provides 10 GB Ethernet switching capability in the SwitchBlade x3112 Sw
SwitchBlade x3112 Installation Guide37AT-SBx31XZ4LED The AT-SBx31XZ4 XFP Line Card has one LED per port as displayed in Figure 14 and described in Tab
Chapter 1: Overview38AT-SBx3161 System Power SupplyThe AT-SBx3161 System Power Supply provides the power for all components installed in the SwitchBla
SwitchBlade x3112 Installation Guide39Table 10. Status LED Description on the AT-SBx3161 System Power SupplyLED State DescriptionACSolid Green The A
Chapter : 4Translated Safety StatementsImportant: The indicates that a translation of the safety statement is available in a PDF document titled “Tr
Chapter 1: Overview40AT-SBx3165 PoE Power SupplyThe AT-SBx3165 PoE Power Supply provides the PoE power for the AT-SBx31GP24 PoE Line Cards. The AT-SB
SwitchBlade x3112 Installation Guide41Table 11. Status LED Description on the AT-SBx3165 PoE Power SupplyLED State DescriptionACSolid Green The AC p
Chapter 1: Overview42AT-SBx31FAN TrayThe AT-SBx31FAN Tray consists of four fans with speed control and status circuitry. It is a field replaceable ass
SwitchBlade x3112 Installation Guide43AT-SBx31FAN Tray POWER LEDThe AT-SBx31FAN Tray has one POWER LED as displayed in Figure 20 and described in Tabl
Chapter 1: Overview44
45Chapter 2InstallationThis chapter describes how to install the SwitchBlade x3112 in an equipment rack. This chapter contains the following sections:
Chapter 2: Installation46Reviewing Safety PrecautionsPlease review the following safety precautions before you begin to install the switch. NoteThe
SwitchBlade x3112 Installation Guide47All Countries: Install product in accordance with local and National Electrical Codes. E8Warning: When install
Chapter 2: Installation48Caution: Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of th
SwitchBlade x3112 Installation Guide49Selecting a Site for the SwitchBlade x3112Observe the following requirements before installing your switch in an
5Preface ...
Chapter 2: Installation50Installing the AT-SBx3112 ChassisThe AT-SBx3112 Chassis is designed for rack mounted installation only. To install the AT-SBx
SwitchBlade x3112 Installation Guide51Preparing the Equipment RackTo prepare for the installation of the SwitchBlade x3112 Switch into your equipment
Chapter 2: Installation522. Identify the lowest 1/2” screw hole pattern on the rack mounting rails within the space reserved for the AT-SBx3112 Chassi
SwitchBlade x3112 Installation Guide532. Ensure that the following hardware components are included in your package. If any item is missing or damaged
Chapter 2: Installation54Figure 23. Rack Mounting Bracket LocationsNoteIf you elect to mount the rack mount brackets in position “E”, the two chassis
SwitchBlade x3112 Installation Guide55Figure 24. Rack Bracket Locations for Reverse Position of ChassisFront panel facingtowards the rear of the rackF
Chapter 2: Installation56Installing the AT-SBx3112 Chassisin Equipment RackTo install the AT-SBx3112 Chassis into the equipment rack, perform the foll
SwitchBlade x3112 Installation Guide573. With the bottom of the rack mount ears resting on the two rack mount screws, tilt the top of the chassis back
Chapter 2: Installation58Installing the Chassis Ground LugA terminal lug is provided with the AT-SBx3112 Chassis to provide a permanent connection to
SwitchBlade x3112 Installation Guide595. Install the ground lug as displayed in Figure 31.Figure 31. Installing the Ground Lug and Wire6. Connect oppo
Contents6Chapter 2: Installation ...
Chapter 2: Installation60Protection Against Electrostatic Discharge (ESD)Proper ESD protection is required when handling the SwitchBlade x3112 line ca
SwitchBlade x3112 Installation Guide61Installing the AT-SBx3161 System Power SupplyThe SwitchBlade x3112 can host up to four power supplies consisting
Chapter 2: Installation623. Remove the power supply from the shipping package.NoteStore the packaging material in a safe location. You must use the or
SwitchBlade x3112 Installation Guide636. Align and insert the AT-SBx3161 power supply into the slot you have chosen. Figure 35 on page 63 shows the po
Chapter 2: Installation648. If you have a second (redundant) AT-SBx3161 System Power Supply to install and the first power supply is installed in slot
SwitchBlade x3112 Installation Guide65Installing the AT-SBx3165 PoE Power SupplyTo install the AT-SBx3165 PoE Power Supply, perform the following proc
Chapter 2: Installation66Figure 37. Unlock the Handle on the AT-SBx3165 PoE Power Supply6. Align and insert the AT-SBx3165 in slot A. See Figure 38.Ca
SwitchBlade x3112 Installation Guide677. Move the locking handle of the power supply to the locked or down position as displayed in Figure 39. Figure
Chapter 2: Installation68Installing the AT-SBx31CFC Fabric Control CardPerform the following procedure to install the AT-SBx31CFC Card:CautionThe AT-S
SwitchBlade x3112 Installation Guide695. Remove the battery insulator between the battery and the battery clip by pulling out the insulator tab as sho
7List of FiguresFigure 1: Front View of the AT-SBx3112 Chassis ...
Chapter 2: Installation707. Insert the card into the slot until you feel it make contact with the connector on the chassis backplane as displayed in F
SwitchBlade x3112 Installation Guide719. Finger tighten the two thumbscrews on each side of the card as displayed in Figure 45 to attach it to the fro
Chapter 2: Installation72Installing the AT-SBx31GP24 PoE Line CardPerform the following procedure to install the AT-SBx31GP24 PoE Line Card:CautionThe
SwitchBlade x3112 Installation Guide733. Align the line card with the internal chassis card guides in the selected slot of the AT-SBx3112 Chassis. Fig
Chapter 2: Installation74Figure 47. Inserting the AT-SBx31GP24 PoE Line Card5. Finger tighten the two thumbscrews on each side of the line card as dis
SwitchBlade x3112 Installation Guide75Installing the AT-SBx31XZ4 XFP Line CardPerform the following procedure to install the AT-SBx31XZ4 Line Card:Cau
Chapter 2: Installation76Figure 49. Aligning the AT-SBx31XZ4 XFP Line Card in the Chassis Slot4. Insert the line card into the slot as displayed in Fi
SwitchBlade x3112 Installation Guide776. With a # 2 Phillips head screw driver, torque both thumbscrews to .56 Nm (5 lb-in) maximum.7. Repeat steps 2
Chapter 2: Installation78Installing an XFP TransceiverTo install an XFP transceiver in the AT-SBx31XZ4 Line Card, perform the following procedure:1. R
SwitchBlade x3112 Installation Guide79Replacing the AT-SBx31FAN TrayThe AT-SBx31FAN Tray can only be replaced in the vertical chassis slot located on
List of Figures8Figure 51: Tightening Thumb Screws on the AT-SBx31XZ4 XFP Line Card ...
Chapter 2: Installation80Figure 54. Inserting the AT-SBx31FAN Tray into the ChassisPOESYSTEMESDPOESYSTEM02468101357911ACDCFAULTSBx31611811SBx31FANPOWE
SwitchBlade x3112 Installation Guide813. Finger tighten the thumbscrew on the bottom of the AT-SBx31FAN Tray as displayed in Figure 55 to attach it to
Chapter 2: Installation82Cabling the Twisted-Pair or Fiber Optic PortsObserve the following guidelines when connecting a twisted-pair or fiber optic c
SwitchBlade x3112 Installation Guide83Installing the Chassis Blank PanelsTen blank panels are supplied with the AT-SBx3112 Chassis. These panels must
Chapter 2: Installation84Applying A/C Power to the SwitchBlade x3112If you have not already installed the power supply(s), go to the “Installing the A
SwitchBlade x3112 Installation Guide85Figure 57. Connecting AC Power Cord in rear of AT-SBx3112 Chassis 4. Verify that the socket-outlet from which th
Chapter 2: Installation866. Verify that the power supply POWER LED is green. If the LED is OFF, refer to Table 10 on page 39 or Table 11 on page 41 fo
SwitchBlade x3112 Installation Guide87Starting a Local Management SessionThe procedure in this section explains how to start a local (out-of-band) man
Chapter 2: Installation88NoteThe port settings are for a DEC VT100 or ANSI terminal, or an equivalent terminal emulator program. 3. Press Enter.You ar
89Chapter 3TroubleshootingThis chapter contains information about how to troubleshoot the SwitchBlade x3112 in the event that a problem occurs.NoteIf
9Table 1. Safety Symbols ...
Chapter 3: Troubleshooting90PSU Fault LED Flashing Amber on AT-SBx31CFC Fabric Control CardCheck the PSU System Status LED on the front of the AT-SBx3
SwitchBlade x3112 Installation Guide91FAN Fault LED Flashing Amber on AT-SBx31CFC Fabric Control CardCheck the FAN System LED on the front panel of th
Chapter 3: Troubleshooting92SBx Status LEDs Flashing Amber on AT-SBx31CFC Fabric Control CardIf a SBx Status LED is flashing amber, the line card has
SwitchBlade x3112 Installation Guide93Link LED is Off on AT-SBx31GP24 PoE Line CardUnder normal operating conditions for a port with an active LINK st
Chapter 3: Troubleshooting94PoE Device is not Receiving Power on AT-SBx31GP24 PoE Line CardIf you attached a powered device (PD) to a port on a AT-SBx
SwitchBlade x3112 Installation Guide95Port LED is Off on AT-SBx31XZ4 XFP Line CardFor fiber optic uplink ports that have an XFP transceiver installed,
Chapter 3: Troubleshooting96 Verify that the XFP transceiver is IEEE 802.3ae (10G Ethernet) and XFP MSA compliant. If an XFP transceiver meets a “Fib
SwitchBlade x3112 Installation Guide97Cannot Establish a Local (Out-of-Band) Management SessionIf you are unable to establish a local (out-of-band) ma
Chapter 3: Troubleshooting98
99Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (W x D x H): AT-SBx3112 Chassis 48.03 cm x 38.79 cm x 31.01 cm (18.91 in x 15.2
Komentáře k této Příručce