Meter command reference QOS
7-47
iMG/RG Software Reference Manual (Quality of Service)
Example --> meter delete profile mp1
See also METER ADD PROFILE SRTCM
METER ADD PROFILE TOKENBUCKET
METER ADD PROFILE TRTCM
7.1.6.1.6 METER LIST PROFILES
Syntax METER LIST PROFILES
Description This command lists all of the meter profiles that were created using the METER ADD
PROFILE commands. It displays the following information about meter profiles:
•Name
Type of algorithm used
CIR value (in kbps)
•CBS value (in bytes)
EBS value (for algorithm type srtcm only)
PIR value (for algorithm type trtcm only)
PBS value (for algorithm type trtcm only)
Green action
Yellow action (for algorithm types trtcm and srtcm only)
•Red action
Example --> meter list profiles
Meter Profiles:
Name| Type | CIR | CBS | PIR | PBS | EBS |Green | Yellow| Red
| |kbps |bytes|kbps |bytes|bytes| | |
----|------------|-----|-----|-----|-----|-----|------|-------|-----
mp1| tokenbucket| 80 |10000| | | | Pass | | Drop
mp2| srtcm | 80 |10000| | |25000| Pass | Pass | Drop
mp3| trtcm | 80 |10000| 120 |15000| | Pass | Pass | Drop
--------------------------------------------------------------------
Option Description Default Value