AT-iMG606BD Multiservice Gateway Installation Guide
41
19. Connect the power cord from the AT-RG005G battery
backup unit or the 12V, 1.5A AC/DC adapter from
Allied Telesyn to the POWER connector on the
gateway, as shown in Figure 23. If you are using the
battery backup unit, you must use the AT-RG008
power cable. (The AT-RG005G battery backup unit
must be earthed.) Refer to Chapter A, “Technical
Specifications” on page 45 for AT-iMG606BD power
specifications.
Figure 23. Plugging in the Power Cord
The PWR LED should light green.
Warning
Electrical-Type Class 1 Equipment: This equipment
must be earthed. The power plug must be connected
to a properly wired earth ground socket outlet. An
improperly wired socket outlet could place hazardous
voltages on accessible metal parts. 6