Strany 1 - User’s Guide

Management SoftwareAT-S47◆User’s GuideFOR THE AT-WD1008 WAVELENGTH DIVISION MULTIPLEXER AND AT-WDM02 MANAGEMENT MODULEVERSION 1.0®PN 613-50371-00 Rev

Strany 2 -  2003 Allied Telesyn, Inc

Preface10Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.WarningWarnings inform you that per

Strany 3 - Table of Contents

Section III: Command Line Interface100SET SYSTEMSyntaxset system [name=name] [location=location] [contact=contact] Parametersname Specifies the name

Strany 4 - Command Line Interface

AT-S47 Management Software User’s Guide101SHOW SYSTEMSyntaxshow systemParametersNone.DescriptionThis command displays the name, location, and contact

Strany 5

Section III: Command Line Interface102SET SNMP COMMUNITY-STRINGSyntaxset snmp getcommunity=string|setcommunity=string|trapcommunity=stringParametersg

Strany 6

AT-S47 Management Software User’s Guide103SET SNMP TRAPSyntaxset snmp trap=0|1|2|3|4|allParameterstrap Specifies the trap to be transmitted to a manag

Strany 7 - List of Figures

Section III: Command Line Interface104DescriptionYou can use this command to control which multiplexer traps are sent to the management workstations.

Strany 8

AT-S47 Management Software User’s Guide105SHOW SNMPSyntaxshow snmp ParametersNone. DescriptionThis command displays the following information:❑ IP add

Strany 9 - How This Guide is Organized

Section III: Command Line Interface106PINGSyntaxping ipaddress=ipaddressParametersipaddress Specifies the IP address of the end node to be pinged by

Strany 10 - Document Conventions

AT-S47 Management Software User’s Guide107RESTART REBOOTSyntaxrestart rebootParametersNone.DescriptionThis command resets the management module. Reset

Strany 11

Section III: Command Line Interface108SHOW DIAGSyntaxshow diagParametersNone.DescriptionThis command tests the components of the multiplexer. Example

Strany 12 - Contacting Allied Telesyn

AT-S47 Management Software User’s Guide109SHOW PORT COUNTERSyntaxshow port=ports|all counter [refresh]Parametersport The number of the GBIC port (1 to

Strany 13 - Getting Started

AT-S47 Management Software User’s Guide11Where to Find Web-based GuidesThe installation and user guides for all Allied Telesyn products are available

Strany 14

Section III: Command Line Interface110RESET PORT COUNTERSyntaxreset port=ports|all counterParametersport The number of the port whose RLL error stati

Strany 15 - Local Management Session

111Chapter 12Module CommandsThe commands in this section display status information about the ports and modules in the multiplexer. You can also use t

Strany 16 - Section I: Getting Started

Section III: Command Line Interface112SET LOCAL PORTSyntaxset local port=port|all mode=active|shutdownParametersport Specifies a GBIC port on the mul

Strany 17 - Management

AT-S47 Management Software User’s Guide113SET REMOTE PORTSyntaxset remote port=port|all mode=active|shutdownParametersport Specifies a GBIC port. You

Strany 18

Section III: Command Line Interface114Taken together, the two commands SET LOCAL PORT and SET REMOTE PORT give you complete control over a GBIC port’

Strany 19 - Using the Terminal Interface

AT-S47 Management Software User’s Guide115SHOW MODULESyntaxshow module=module|allParametermodule Specifies the number of the port or module in the mul

Strany 20 - Telnet Management Session

Section III: Command Line Interface116SET MODULE NAMESyntaxset module=number name=nameParametermodule Specifies the number of the port or module in t

Strany 21 - < to > _

AT-S47 Management Software User’s Guide117SHOW GBIC MODULESyntaxshow gbic module=number|allParametermodule Specifies the GBIC port number whose status

Strany 22 - Quitting a

Section III: Command Line Interface118SHOW GBIC VENDOR MODULESyntaxshow gbic vendor module=number|allParametermodule Specifies the GBIC port number w

Strany 23 - SNMP Management Session

119Chapter 13Link Test CommandsThis chapter contains the following commands: NoteFor background information on this feature, refer to Link Test on pag

Strany 24 - Menu Interface

Preface12Contacting Allied TelesynTo contact Technical Support by phone, find your country or region in the table below.You can also contact Technical

Strany 25 - Basic Multiplexer Parameters

Section III: Command Line Interface120ENABLE MODULE LINKTESTSyntaxenable module=9|10|all linktestParametersmodule Specifies the multiplexing port who

Strany 26 - Section II: Menu Interface

AT-S47 Management Software User’s Guide121DISABLE MODULE LINKTESTSyntaxdisable module=9|10|all linktestParametersmodule Specifies the multiplexing por

Strany 27

122Chapter 14Missing Link CommandsThis chapter contains the following commands:NoteFor background information on this feature, refer to Missing Link o

Strany 28 - Parameter Description

AT-S47 Management Software User’s Guide123ENABLE MISSLINKSyntaxenable misslinkParametersNone.DescriptionThis command activates the Missing Link featur

Strany 29 - Naming the Multiplexer

Section III: Command Line Interface124DISABLE MISSLINKSyntaxdisable misslinkParametersNone.DescriptionThis command deactivates the Missing Link featu

Strany 30

125Chapter 15Activity Log CommandsThis section describes the commands that control the Activity Log. The Activity Log contains a list of multiplexer o

Strany 31

Section III: Command Line Interface126SHOW LOGSyntaxshow log [status]Parametersstatus Displays the current status of the Activity Log. Status will be

Strany 32 - Pinging a Remote System

AT-S47 Management Software User’s Guide127ENABLE LOGSyntaxenable logParametersNone. DescriptionThis command activates the Activity Log. You can use th

Strany 33

Section III: Command Line Interface128DISABLE LOGSyntaxdisable logParametersNone. DescriptionThis command disables the Activity Log. Disabling the lo

Strany 34

AT-S47 Management Software User’s Guide129SET LOGSyntaxset log syslogserver=ipaddress facilitycode=numberParameterssyslogserver Specifies the IP addre

Strany 35 - Configuring the RS-232 Port

13Section IGetting StartedThe chapter in this section provides a brief overview of the AT-S47 Management Software and explains how to start a manageme

Strany 36 - 4. Return to the Main Menu

130Chapter 16AT-S47 Interface Security CommandsThe commands in this section are used to configure the security features of the AT-S47 Management Softw

Strany 37 - Return to Main Menu

AT-S47 Management Software User’s Guide131DISABLE TELNETDeactivates the Telnet management feature of the AT-WDM02 Management Module so that the multip

Strany 38

Section III: Command Line Interface132SET PASSWORDSyntaxset passwordParametersNone.DescriptionThis command is used to assign a new password to the AT

Strany 39

AT-S47 Management Software User’s Guide133SHOW CONSOLESyntaxshow consoleParametersNone.DescriptionThis command displays the following information:❑ Cu

Strany 40 - Running Diagnostics

Section III: Command Line Interface134ENABLE CONSOLESyntaxenable console [echo]ParametersNone.DescriptionThis command activates local management on t

Strany 41

AT-S47 Management Software User’s Guide135DISABLE CONSOLESyntaxdisable console [echo]ParametersNone.DescriptionThis command deactivates local manageme

Strany 42

Section III: Command Line Interface136SET CONSOLESyntaxset console [timeout=seconds] [speed=2400|4800|9600|19200]Parameterstimeout Specifies the cons

Strany 43 - Module Parameters

AT-S47 Management Software User’s Guide137ENABLE TELNETSyntaxenable telnetParametersNone.DescriptionThis command activates Telnet management of the mu

Strany 44 - Displaying Module Status

Section III: Command Line Interface138DISABLE TELNETSyntaxdisable telnetParametersNone.DescriptionThis command deactivates Telnet management of the m

Strany 45 - 1 thru 8

AT-S47 Management Software User’s Guide139SET TELNETSyntaxset telnet tcpport=numberParameterstcpport Specifies the TCP port number used for Telnet man

Strany 46 - Module Status

14Chapter 1Getting StartedThe AT-S47 Management Software and the management interface simplify the task of monitoring and managing your Allied Telesyn

Strany 47

140Chapter 17AT-S47 Image Download CommandsThe commands in this section are used to load a new version of the AT-S47 Management Software onto the AT-W

Strany 48 - Configuring a Module

AT-S47 Management Software User’s Guide141LOADSyntaxloadParametersNone.DescriptionThis command is used to download a new version of the AT-S47 Managem

Strany 49 - Port Settings

Section III: Command Line Interface142❑ Downloading new software does not interrupt the flow of traffic through the multiplexer.❑ The transfer protoc

Strany 50

AT-S47 Management Software User’s Guide143SET LOADER PASSWORDSyntaxset loader password=passwordParameterpassword Specifies the new loader password. Th

Strany 51

144Appendix AAT-S47 Default SettingsThis appendix lists the default settings for AT-S47 Version 1.0.Settings DefaultIP Address 0.0.0.0Subnet Mask 0.0.

Strany 52 - Module Settings

AT-S47 Management Software User’s Guide145Multiplexing and GBIC PortsStatus EnabledLink Test DisabledRS-232 PortTerminal mode VT-100-compatible / ANSI

Strany 53 - Power Supply

146Appendix BAT-WDM02 Activity Log EventsThis appendix contains the multiplexer events that appear in the Activity Log. The activities are divided int

Strany 54 - Settings

AT-S47 Management Software User’s Guide147Change of SettingsModule StatusD:H:M:S: Mx MN ‘yyyyy’ Module Name changed.Mx: Module NumberMN: Module Name (

Strany 55 - Link Test

Appendix B: AT-WDM02 Activity Log Events148Omega OptionsD:H:M:S: Con-PW Password changed.D:H:M:S: Con-TO ‘xxx’ Interface Timeout changed.‘xxx’: Timeo

Strany 56 - Overview

AT-S47 Management Software User’s Guide149D:H:M:S: SNMP-Location ‘xxxxx’Location changed.‘xxxxx’: LocationD:H:M:S: SNMP-Contact ‘xxxxx’Contact changed

Strany 57

AT-S47 Management Software User’s Guide15Local Management SessionYou establish a local management session with an AT-WD1008 multiplexer using the RS-2

Strany 58

Appendix B: AT-WDM02 Activity Log Events150Terminal ConfigurationD:H:M:S: Term-F Terminal set to Full Duplex (echo)D:H:M:S: Term-H Terminal set to Ha

Strany 59 - Missing Link

151IndexAaccess methodsdefined, 14disabling, 68enabling, 68local access, 15, 144remote access, 20, 23, 144Activity LogChange of Condition events, 146C

Strany 60

Index152SET SYSTEM, 100SET TELNET, 139SHOW CONFIG, 99SHOW CONSOLE, 133SHOW DIAG, 108SHOW GBIC MODULE, 117SHOW GBIC VENDOR MODULE, 118SHOW LOG, 126SHOW

Strany 61 - Failure of fiber cable

AT-S47 Management Software User’s Guide 153IP parameters, activity events, 148LLink Testdefault setting, 145defined, 56disabling, 58, 121enabling, 58,

Strany 62

Index154SHOW GBIC VENDOR MODULE command, 118SHOW LOG command, 126SHOW MODULE command, 115SHOW PORT COUNTER command, 109SHOW SNMP command, 105SHOW SYST

Strany 63 - Activity Monitor

Section I: Getting Started16An example of a blank HyperTerminal Blank Screen is displayed in Figure 1.Figure 1 HyperTerminal Opening Screen3. Press

Strany 64 - 0:00:00:00 M11-PA Online

AT-S47 Management Software User’s Guide17Quitting a LocalManagementSessionTo end a local management session, return to the Main Menu and select Quit.

Strany 65 - Specifying a SysLog Server

Section I: Getting Started18Main Menu Tree Module status and configuration❑ Module Status Menu❑ Enable missing linkDisable missing linkStatistics❑ In

Strany 66

AT-S47 Management Software User’s Guide19Using the Terminal InterfaceIf you are using a DEC VT100 or ANSI (the default) terminal configuration, refer

Strany 67 - Password

Copyright  2003 Allied Telesyn, Inc. 960 Stewart Drive Suite B, Sunnyvale, CA 94085 USAAll rights reserved. No part of this publication may be reprod

Strany 68 - Timeout Value

Section I: Getting Started20Telnet Management Session Any management workstation on your network that has the Telnet application protocol can be used

Strany 69 - Access Method Description

AT-S47 Management Software User’s Guide21The Run window is displayed in Figure 4. Figure 4 Run Window2. Type telnet in the Open text box.3. Select OK

Strany 70

Section I: Getting Started22Quitting aTelnetManagementSessionTo end a Telnet management session, return to the Main Menu and type Quit. If you are us

Strany 71 - Obtaining Software Updates

AT-S47 Management Software User’s Guide23SNMP Management SessionAnother way to remotely manage an AT-WD1008 multiplexer is with an SNMP application pr

Strany 72

24Section IIMenu InterfaceThe chapters in this section explain how to manage an AT-W1008 Multiplexer using the AT-S47 interface. This section contains

Strany 73

25Chapter 2Basic Multiplexer Parameters and ProceduresThis chapter contains the following procedures:❑ Configuring Basic Multiplexer Parameters on pag

Strany 74

Section II: Menu Interface26Configuring Basic Multiplexer ParametersThis section contains the procedure for setting the following information:❑ IP ad

Strany 75

AT-S47 Management Software User’s Guide27The IP Parameters menu is displayed in Figure 7.Figure 7 IP Parameters Menu3. Enter or change the parameters

Strany 76

Section II: Menu Interface284. After you have adjusted the parameters, return to the Main Menu.Gateway AddressSpecifies the IP address of the default

Strany 77

AT-S47 Management Software User’s Guide29Naming the MultiplexerThis procedure assigns a name to the multiplexer. The name is displayed in all manageme

Strany 78 - Formatting

3Table of ContentsList of Figures ...

Strany 79 - Command Reference

Section II: Menu Interface30Configuring the Trap ParametersThis section contains the procedure for specifying which traps are to be sent to the SNMP

Strany 80 - Line Commands

AT-S47 Management Software User’s Guide31The traps are defined in the table below:Table 1 SNMP Traps4. After you have adjusted the trap settings, ret

Strany 81 - Multiplexer

Section II: Menu Interface32Pinging a Remote SystemThe procedure in this section tests whether a valid link exists between the multiplexer and anothe

Strany 82

AT-S47 Management Software User’s Guide333. Enter the IP address of the device you want the multiplexer to ping.The Activity Monitor in Figure 11 is d

Strany 83

Section II: Menu Interface34Resetting the Management ModuleThere are two ways to reset the management software:❑ Pressing the RESET switch located on

Strany 84 - Activity Log

AT-S47 Management Software User’s Guide35Configuring the RS-232 PortThe default settings for the RS-232 port on the front panel of the management modu

Strany 85 - Security

Section II: Menu Interface364. Return to the Main Menu.Changes to the RS-232 port parameters take effect the next time you start a local management s

Strany 86 - Download

AT-S47 Management Software User’s Guide37Displaying RLL Error StatisticsThe Statistics Menu displays Run-length-limit (RLL) Errors. An RLL error is a

Strany 87 - Basic Command Line Commands

Section II: Menu Interface38❑ To view the port statistics, select Individual channel overview. The Individual channel overview menu is displayed in F

Strany 88

AT-S47 Management Software User’s Guide39To view the RLL Errors that have occurred in both the transmit (TX) and the receive (RX) ports of a channel,

Strany 89

4Chapter 3Module Parameters ...

Strany 90

Section II: Menu Interface40Running DiagnosticsThe AT-S47 Management Software interface has an option for running diagnostic self-tests on the AT-WD1

Strany 91

AT-S47 Management Software User’s Guide41To run the diagnostic tests, perform the following procedure:1. From the Main Menu, select Administration. Th

Strany 92 - Basic Multiplexer Commands

Section II: Menu Interface42The test results are displayed as follows:❑ Flash PROM = Good or Failed❑ RAM = Good or Failed❑ Serial Interface = Good or

Strany 93

43Chapter 3Module ParametersThis chapter contains the following procedures:❑ Displaying Module Status on page 44❑ Configuring a Module on page 48

Strany 94

Section II: Menu Interface44Displaying Module StatusThe Module Status Menu displays the operating status of the following modules:❑ GBIC ports (CH1 t

Strany 95

AT-S47 Management Software User’s Guide45Table 2 Module Operating StatusModule NoModule DescriptionModule Status1 thru 8GBIC ports• CH1• CH2• CH3• CH

Strany 96

Section II: Menu Interface469 and 10Multiplexing ports• WEST (OPT A)• EAST (OPT B)The status information for a multiplexing port varies depending on

Strany 97 - ENABLE BOOTP

AT-S47 Management Software User’s Guide4713Optional redundant power supplyTx/Status - Indicates the operating status of the module.• On: Indicates tha

Strany 98 - DISABLE BOOTP

Section II: Menu Interface48Configuring a ModuleThis section contains instructions on how to configure a module. It should be noted that each type of

Strany 99 - SHOW CONFIG

AT-S47 Management Software User’s Guide49The fields in the Module Configuration menu for a GBIC module are defined in the table below:3. Return to the

Strany 100 - SET SYSTEM

AT-S47 Management Software User’s Guide5Chapter 11Basic Multiplexer Commands ...

Strany 101 - SHOW SYSTEM

Section II: Menu Interface50The Module Configuration menu for a multiplexing port is displayed in Figure 22.Figure 22 Example of Module Configuratio

Strany 102 - SET SNMP COMMUNITY-STRING

AT-S47 Management Software User’s Guide51Module nameSpecifies the name for the selected multiplexing port.• The module name can be up to 20 alphanumer

Strany 103 - SET SNMP TRAP

Section II: Menu Interface523. Return to the Module Status Menu.ManagementModule SettingsTo configure the settings of the AT-WDM02 Management Module,

Strany 104

AT-S47 Management Software User’s Guide53The fields in the Module Configuration menu for the management module are defined in the table below:3. Retur

Strany 105 - SHOW SNMP

Section II: Menu Interface543. Return to the Module Status Menu.Fan ModuleSettingsTo configure the settings of the fan modules (FAN A or FAN B), perf

Strany 106

55Chapter 4Link TestThis chapter contains the following procedures:❑ Overview on page 56❑ Enabling or Disabling Link Test on page 58

Strany 107 - RESTART REBOOT

Section II: Menu Interface56OverviewThe Link Test feature is a fast and easy way for you to test the link integrity between local and remote multiple

Strany 108 - SHOW DIAG

AT-S47 Management Software User’s Guide57❑ Try cleaning the fiber connector.❑ Use a fiber optic test to verify that attenuation is less than 25 dB.Not

Strany 109 - SHOW PORT COUNTER

Section II: Menu Interface58Enabling or Disabling Link Test To enable or disable a Link Test on a multiplexing port, perform the following procedure:

Strany 110 - RESET PORT COUNTER

59Chapter 5Missing LinkThis chapter contains the following procedures:❑ Overview on page 60❑ Enabling or Disabling Missing Link on page 62

Strany 111 - Module Commands

6Chapter 17AT-S47 Image Download Commands ...

Strany 112 - SET LOCAL PORT

Section II: Menu Interface60OverviewThe Missing Link feature of the AT-WD1008 unit enables the multiplexers to pass the “Link” status of their connec

Strany 113 - SET REMOTE PORT

AT-S47 Management Software User’s Guide61If a loss of connection occurs between two multiplexing ports, the links are dropped on the corresponding GBI

Strany 114

Section II: Menu Interface62Enabling or Disabling Missing LinkTo enable or disable Missing Link, perform the following procedure:1. From the Main Men

Strany 115 - SHOW MODULE

63Chapter 6Activity MonitorThis chapter contains the following procedures:’❑ Displaying the Activity Monitor on page 64❑ Specifying a SysLog Server on

Strany 116 - SET MODULE NAME

Section II: Menu Interface64Displaying the Activity MonitorThe management software keeps a list of multiplexer events, such as the removal of a GBIC

Strany 117 - SHOW GBIC MODULE

AT-S47 Management Software User’s Guide65Specifying a SysLog ServerTo transmit the multiplexer events to a syslog server, perform the following proced

Strany 118 - SHOW GBIC VENDOR MODULE

66Chapter 7AT-S47 Interface SecurityThis chapter describes the security features of the AT-S47 interface. These features allow you to configure the in

Strany 119 - Link Test Commands

AT-S47 Management Software User’s Guide67Configuring the AT-S47 Interface SecurityModifying theManagementPasswordTo prevent unauthorized individuals f

Strany 120 - ENABLE MODULE LINKTEST

Section II: Menu Interface68Specifying aTimeout ValueSpecifying a timeout value is a way to prevent unauthorized individuals from using the interface

Strany 121 - DISABLE MODULE LINKTEST

AT-S47 Management Software User’s Guide694. Return to the Main Menu.Remote Omega EnabledNo Remote OmegaThese two selections allow you to control wheth

Strany 122 - Missing Link Commands

7List of FiguresFigure 1: HyperTerminal Opening Screen ...

Strany 123 - ENABLE MISSLINK

70Chapter 8AT-S47 Image DownloadThis chapter explains how to obtain new versions of the AT-S47 Management Software and how to download the software on

Strany 124 - DISABLE MISSLINK

AT-S47 Management Software User’s Guide71Obtaining Software UpdatesNew releases of the AT-S47 Management Software are available from the Allied Telesy

Strany 125 - Activity Log Commands

Section II: Menu Interface72Using XModem to Upgrade the Management SoftwareThe AT-S47 Management Software interface supports software upgrades to the

Strany 126 - SHOW LOG

AT-S47 Management Software User’s Guide733. Enter Y to start the download process or N to cancel.If you select Y, the status message in Figure 29 is d

Strany 127 - ENABLE LOG

Section II: Menu Interface748. Click Send. The software immediately begins to download onto the management module. The Xmodem File Send window in Fig

Strany 128 - DISABLE LOG

AT-S47 Management Software User’s Guide75Using TFTP to Upgrade the Management SoftwareIf your network is using the TCP/IP protocol, you can use a work

Strany 129

76Section IIICommand Line InterfaceThis section contains the command line commands for managing the AT-WD1008 multiplexer. This section contains the f

Strany 130 - Commands

77Chapter 9Getting StartedStarting a Command Line Management SessionIn order to manage an AT-WD1008 multiplexer using the command line commands, you m

Strany 131 - Command Function Page

Section III: Command Line Interface78Key Features The following features are supported in the command line interface:❑ Command history using the up a

Strany 132 - SET PASSWORD

AT-S47 Management Software User’s Guide79Command Reference❑ Basic Command Line Commands on page 80❑ Basic Multiplexer Commands on page 81❑ Module Comm

Strany 133 - SHOW CONSOLE

8PrefaceThis guide contains instructions on how to use the AT-S47 Management Software and the management interface to manage your AT-WD1008 Gigabit Et

Strany 134 - ENABLE CONSOLE

Section III: Command Line Interface80Basic CommandLine CommandsMENUmenuDisplays the AT-S47 Main Menu.HELPhelp [command|function]Displays help message

Strany 135 - DISABLE CONSOLE

AT-S47 Management Software User’s Guide81BasicMultiplexerCommandsSET IPset ip ipaddress=ipaddress mask=subnetmask gateway=ipaddress manager|1|2|3|4=ip

Strany 136 - SET CONSOLE

Section III: Command Line Interface82SET SNMP TRAPset snmp trap=0|1|2|3|4|allSets which traps the management workstations are to receive.SHOW SNMPsho

Strany 137 - ENABLE TELNET

AT-S47 Management Software User’s Guide83ModuleCommandsSET LOCAL PORTset local port=port|all mode=active|shutdownDisables the laser on a GBIC port.SET

Strany 138 - DISABLE TELNET

Section III: Command Line Interface84Missing LinkCommandsENABLE MISSLINKenable misslinkActivates Missing Link.DISABLE MISSLINKdisable misslinkDeactiv

Strany 139 - SET TELNET

AT-S47 Management Software User’s Guide85AT-S47 InterfaceSecurityCommandsSET PASSWORDset passwordAssigns a new password to the AT-S47 management inter

Strany 140 - AT-S47 Image Download

Section III: Command Line Interface86SET TELNETset telnet tcpport=numberConfigures the TCP port number used for Telnet management.AT-S47 ImageDownloa

Strany 141

87Chapter 10Basic Command Line CommandsThis chapter contains the following commands:Command Function PageMENUDisplays the AT-S47 Main Menu. 88HELPDisp

Strany 142

Section III: Command Line Interface88MENUSyntaxmenuParametersNone.DescriptionThis command displays the Main Menu of the AT-S47 Management Software.Ex

Strany 143 - SET LOADER PASSWORD

AT-S47 Management Software User’s Guide89HELPSyntaxhelp [command|function]Parameterscommand Specifies the command whose help message you want to view.

Strany 144 - AT-S47 Default Settings

AT-S47 Management Software User’s Guide9How This Guide is OrganizedThis manual is divided into three sections. Section I: Getting StartedThis section

Strany 145 - Settings Default

Section III: Command Line Interface90HISTORYSyntaxhistory [clear]Parametersclear Clears the history log.DescriptionThis command displays the history

Strany 146 - AT-WDM02 Activity Log Events

AT-S47 Management Software User’s Guide91QUITSyntaxquitParametersNone.DescriptionThis command ends a management session. Examplequit

Strany 147 - Status Activity Explanation

92Chapter 11Basic Multiplexer CommandsThis chapter contains the following commands:Command Function PageSET IPSets the multiplexer’s IP address, subne

Strany 148

AT-S47 Management Software User’s Guide93RESTART REBOOTReboots the management module. 107SHOW DIAGRuns self-diagnostics. 108SHOW PORT COUNTERDisplays

Strany 149

Section III: Command Line Interface94SET IPSyntaxset ip ipaddress=ipaddress mask=subnetmask gateway=ipaddress manager|1|2|3|4=ipaddressParametersipad

Strany 150

AT-S47 Management Software User’s Guide95ExamplesThe following command sets the multiplexer’s IP address to 140.35.22.22, the subnet mask to 255.255.2

Strany 151

Section III: Command Line Interface96SHOW IPSyntaxshow ipParametersNone.DescriptionThis command displays the current values for the following multipl

Strany 152

AT-S47 Management Software User’s Guide97ENABLE BOOTPSyntaxenable bootpParametersNone.DescriptionThis command activates BOOTP on the management module

Strany 153

Section III: Command Line Interface98DISABLE BOOTPSyntaxdisable bootpParametersNone.DescriptionThis command deactivates BOOTP on the multiplexer. The

Strany 154

AT-S47 Management Software User’s Guide99SHOW CONFIGSyntaxshow config [all] Parametersall Displays all current multiplexer settings by command.Descrip